18 - 3 Contents of Parameters
CAUTION
The operating parameters can be preset depending on the application requirements.
The operating parameter presets ( " Setting of Error Output Mode ", " Setting AUTO mode
for Motor Speed Control ", " Setting Fixed Motor Speed ", " Setting Maximum Motor Speed ",
" Selection of External Speed Control Mode ", " Selection of External Motor Start Signal Control
Mode ", " Selection of Air Input Monitoring Override ", " Selection of Motor Speed Control Voltage
/ DC+10V Signal Method ", " Selection of Emergency Stop Function " and, " Error History " ) are
retained in non - volatile memory and will be maintained even if power is disconnected.
Please operate only after con rming contents of parameter settings.
The following parameters can be set.
Setting of Error Output Mode
・ Selection of the error output mode is on " Error (Pin No.
・ When an error occurs the output can be select to ' ON (Closed) ' or ' OFF (Open) '.
・ Signals can be output according to the required machine control logic of the system.
Table. 10
Parameter
Setting AUTO Mode for Motor Speed Control
・ Allows the setting of the manner in which Motor speed can be controlled when the system is being used
in the Controls' AUTO MODE (External Command Signal Control).
・ This parameter selects between speed control with the Motor Speed Adjustment Button (SPEED
⑬ of the Control Panel ② or by External Command Signal through Input / Output Connector A ③ .
Table. 11
Parameter
Setting Fixed Motor Speed
CAUTION
If you set the rotation speed higher than the rotation speed set at
according to
.
・ Allows the Motor speed to be xed.
・ Proactively prevents inadvertent change in speed.
・ The Fixed Motor Speed can set by Control Mode MANUAL or AUTO .
Table. 12
Parameter
84
Error Occurred : Signal is ' OFF (Open) '.
Error Occurred : Signal is ' ON (Closed) '.
Set the Motor Rotation Speed by External Command Signal
through External Input / Output Connector A ③ .
Set the Motor Rotation Speed by Motor Speed Adjustment
Button (SPEED
,
Fixed Motor Speed is enabled.
Fixed Motor Speed is not enabled.
8 : ERR) " of Input / Output Connector A
Set Contents
Set Contents
) ⑬ via the Control Panel ② .
Set Contents
③ .
, rotation speed will be set
,
)

Advertisement

Table of Contents
loading