18 - 3 Contents of Parameters
CAUTION
The operating parameters can be preset depending on the application requirements.
The operating parameter presets ( " Setting of Error Output Mode ", " Setting AUTO mode
for Motor Speed Control ", " Setting Fixed Motor Speed ", " Setting Maximum Motor Speed ",
" Selection of External Speed Control Mode ", " Selection of External Motor Start Signal Control
Mode ", " Selection of Air Input Monitoring Override ", " Selection of Motor Speed Control Voltage
/ DC+10V Signal Method ", " Selection of Emergency Stop Function " and, " Error History " ) are
retained in non - volatile memory and will be maintained even if power is disconnected.
Please operate only after con rming contents of parameter settings.
The following parameters can be set.
①
Setting of Error Output Mode
・ Selection of the error output mode is on " Error (Pin No.
・ When an error occurs the output can be select to ' ON (Closed) ' or ' OFF (Open) '.
・ Signals can be output according to the required machine control logic of the system.
Table. 10
Parameter
②
Setting AUTO Mode for Motor Speed Control
・ Allows the setting of the manner in which Motor speed can be controlled when the system is being used
in the Controls' AUTO MODE (External Command Signal Control).
・ This parameter selects between speed control with the Motor Speed Adjustment Button (SPEED
⑬ of the Control Panel ② or by External Command Signal through Input / Output Connector A ③ .
Table. 11
Parameter
③
Setting Fixed Motor Speed
CAUTION
If you set the rotation speed higher than the rotation speed set at
according to
.
・ Allows the Motor speed to be xed.
・ Proactively prevents inadvertent change in speed.
・ The Fixed Motor Speed can set by Control Mode MANUAL or AUTO .
Table. 12
Parameter
84
Error Occurred : Signal is ' OFF (Open) '.
Error Occurred : Signal is ' ON (Closed) '.
Set the Motor Rotation Speed by External Command Signal
through External Input / Output Connector A ③ .
Set the Motor Rotation Speed by Motor Speed Adjustment
Button (SPEED
,
Fixed Motor Speed is enabled.
Fixed Motor Speed is not enabled.
8 : ERR) " of Input / Output Connector A
Set Contents
Set Contents
) ⑬ via the Control Panel ② .
Set Contents
③ .
, rotation speed will be set
,
)