Introduction

Audio Input MicrophoneMode

This setting applies only to DX80.
The DX80 has microphones in both legs. If you set the microphone mode to Focused, the
microphones can be combined to focus sound sensitivity. As a result, the noise in the room
is suppressed, and you can be heard better when sitting right in front of the video system.
The voice of people not sitting right in front of the system will be suppressed.
If you set the microphone mode to Wide, the system behaves like any other system. The
voice of people sitting beside you will be heard, and also more noise from the room.
We recommend that you use Focused mode when you are the only speaker. Use Wide
mode when several speakers are in front of the system.
Requires user role: ADMIN, INTEGRATOR
Default value: Wide
Value space: Focused/Wide
Focused: Focused sound sensitivity, suppressing sound from sources that are not right
in front of the video system.
Wide: Default microphone operation with normal sound sensitivity.

Audio Ultrasound Mode

This setting applies to the Intelligent Proximity feature. Keep the setting at its default value.
Requires user role: ADMIN, INTEGRATOR
Default value: Dynamic
Value space: Dynamic/Static
Dynamic: The video system adjusts the ultrasound volume dynamically. The volume may
vary up to the maximum level as defined in the Audio Ultrasound Volume MaxVolume
setting.
Static: Use only if advised by Cisco.
D15362.06 DX70 and DX80 Administrator Guide CE9.2, NOVEMBER 2017.
Configuration
Peripherals
Maintenance

Audio Ultrasound MaxVolume

This setting applies to the Intelligent Proximity feature. Set the maximum volume of the
ultrasound pairing message.
Requires user role: ADMIN, INTEGRATOR
Default value: DX80: 70 DX70: 60
Value space: DX80: Integer (0..90) DX70: Integer (0..60)
Select a value in the specified range. If set to 0, the ultrasound is switched off.