Tiny Serial-to-Ethernet Device Server
The following is an overview of the parameters contained in the IP Address Settings section:
Item
IP Address
Address Type
Static IP Address
Subnet Mask
Default Gateway
MAC Address
Virtual COM
TCP Command Port
Command Port Timeout
(Socket Watchdog)
Update Settings
Copyright © 2016 ICP DAS CO., Ltd. All Rights Reserved.
Static IP: If no DHCP server is installed on the network, the network
settings can be configured manually. Refer to
Configuration
for more details.
DHCP: The Dynamic Host Configuration Protocol (DHCP) is a network
application protocol that automatically assigns an IP address to each
device. Refer to
Section 4.3.1.2 Dynamic Configuration
details.
Each tDS-700 connected to the network must have its own unique IP
address. This parameter is used to assign a specific IP address.
This parameter is used to assign the subnet mask for the tDS-700
device. The subnet mask indicates which portion of the IP address is
used to identify the local network or subnet.
This parameter is used to assign the IP Address of the Gateway to be
used by the tDS-700. A Gateway (or router) is a device that is used to
connect an individual network to one or more additional networks.
This parameter is used to set a user-defined MAC address, which must
be in the format FF-FF-FF-FF-FF-FF.
This parameter is used to configure the TCP Command Port to a custom
value depending on your requirement. Note that if the TCP Command
Port configuration setting is completed, the TCP port of serial port will
be change, as follows:
COM1= TCP Command Port + 1
COM2= TCP Command Port + 2
The default TCP Command Port is 10000, Thus, the serial COM
port1/port2 is 10001/10002, and so on.
If the command port does not receive any data from the TCP/IP socket
for a certain period, the tDS-700 can disconnect the socket.
Settings range value: 1 ~ 65535 (seconds);
Default value: 30 (seconds); Disabled: 0;
Click this button to save the revised settings to the tDS-700.
Description
Section 4.3.1.1 Manual
for more
- 37 -