Tiny Serial-to-Ethernet Device Server
Item
Packing Length (bytes)
Serial Ending Chars
(Number[,char1][,char2])
Timeout Between Chars (ms)
Pair-Connection Settings (Client/Server Mode)
Application Mode
Remote Server IP
Remote TCP Port
Submit
The more detailed information regarding pair-connection applications settings, please
refer to the section 5.4 "Pair-Connection Applications".
Note
Copyright © 2016 ICP DAS CO., Ltd. All Rights Reserved.
Description
When the input serial data length reaches to the
value, it will be sent out.
Settings range: 0 ~ 1024; Disabled: 0.
The tDS-700 outputs an Ethernet packet immediately
after the ending-chars pattern is identified from the
incoming serial data. The number of ending-chars can
be 0 (disabled), 1 or 2 chars.
Disabled=0;
1 char: 1,0x0D;
2 chars: 2,0x0D, 0x0A
Set the waiting time after Rx of the response sent
from the device. If the device does not respond within
the timeout value, the tDS-700 will process this
response.
Settings range: 10 ~ 65535; Disabled: 0.
Server
-
-
Click this button to save the revised settings to the tDS-700.
Default
Client
IP address of the remote device
TCP Port number of the remote
device
0
0
10
- 46 -