VERSION 12 / 2012
OPERATING MANUAL
Fine Flow Controller (ZIP52 Finishing)
To clean the fi lter of the Fine-Flow controller, unscrew the plastic
ring nut (1) from the metal body, lift the cup (2) paying attention
to the PTFE gasket on the edge. There pay attention to the
PTFE-Sealing on the edge. Remove the fi lter (3) from the base (4),
pulling it upward, since it has a very simple fi xing (clip). Plunge
the fi ltering cartridge into the solvent, then brush and blow it.
Make sure that the inside of the fi lter is cleaned with fl ushing
agent and is blown out.
Insert the fi lter by pushing it onto the fi lter seat until the fi xing
clip audibly clicks into place. Do not push the fi lter any further, to
avoid damaging it. Reposition the cup making sure the PTFE seal
is in the perfect position. Then screw the ring nut tight.
Filter ZIP52 PF Eco-Finishing
To clean the Filter of the ZIP52 Eco-Finishing unit, simply remove the upper cover (1) from
the fi lter housing (2), by unscrewing it, then unscrew the fi lter's lock-ring (3) and remove
the fi lter element (4).
Remove the internal spring (5). Place the fi lter cartridge and the internal spring into the
fl ushing agent. Then brush and blow them out. Make sure that the inside of the fi lter is
cleaned with fl ushing agent and is blown out.
Reassemble in reverse order, taking care not to damage the plastic seal (6).
ORDER NUMBER DOC 2332848
3
4
1
5
2
B_04053
1
2
3
4
B_04052
6
38