Ending Or Interrupting Work - WAGNER ZIP52 Finishing Operating Manual

Pneumatic double diaphragm pump spray pack
Hide thumbs Also See for ZIP52 Finishing:
Table of Contents

Advertisement

VERSION 12 / 2012
OPERATING MANUAL
The atomizing air pressure should be set to 1-2.5 bar, depending on the paint characteristics.
To obtain perfect atomization and to avoid spray mist, the lowest possible atomizing air
pressure should be used.
In very few cases, the gun must be provided with a very low material pressure and a very
high atomizing air pressure.
Carefully choose the appropriate atomizing cap for the spray gun.
7.2

ENDING OR INTERRUPTING WORK

To stop the pump, simply close the gun - (or any other cut-off device installed along the
delivery pipe).
When the work is completed, close the air cut-off valve. Relieve the pressure in the material
line by opening the return valve or the spray gun.
Dealing with hardening liquids:
In case of hardening liquids such as 2-component mixed resins, the pump, and anything
connected to it, must be thoroughly fl ushed out at the end of working session by using a
solvent suitable for the type of resin being used. The solvent must be left inside the pump,
until its next use.