9.1

SAFETY INSTRUCTIONS

Prior to maintenance and cleaning measures note:
Wear protective clothing and use specifi c protection devices with regard to the nature
of the fl uids involved.
Close the compressed air supply and release the pressure from the pump and pipes
connected to it.
Depending on the operation, disconnect the material and air side connection pipes.
Remove the pump from the base or support it is fastened to. Turn the pump upside-
down over a container suitable for collecting any liquid it may contain.
After the pump has been reassembled and reinstalled following maintenance
operations:
Check the effi ciency of the grounding connection of the individual parts of the pump.
Carry out pressure retention test in accordance with Chapter 6.5.3. Check that no air
fl ows out.
Note: All threads are right-hand threads.
9.2

FILTER CLEANING

This pump has one fi lter inside the suction pipe and another inside the delivery circuit
(Fine-Flow Controller for the ZIP52 Finishing and fi lter for the ZIP52PF Eco-Finishing).
All fi lters must be cleaned frequently. It is also necessary to clean the fi lters when changing
the paint color.
Before cleaning the fi lters, close air cut-off valve and release the pressure contained
inside the pump and the pipes attached to it.
Suction pipe fi lter
To clean the suction pipe fi lter remove the spring, take out the suction fi lter and fi lter disc
and place them in fl ushing agent. Then brush them and blow them off with compressed
air.
B_04059
ORDER NUMBER DOC 2332848
B_04060
37