Commissioning; Safety Regulations - WAGNER ZIP52 Finishing Operating Manual

Pneumatic double diaphragm pump spray pack
Hide thumbs Also See for ZIP52 Finishing:
Table of Contents

Advertisement

VERSION 12 / 2012
OPERATING MANUAL
6.5

COMMISSIONING

6.5.1

SAFETY REGULATIONS

Before carrying out any work, the following points must be observed in accordance with
the operating instructions:
- Observe all safety regulations in accordance with Chapter 4.
- Carry out commissioning properly.
High pressure spray jet!
Danger to life from injecting paint or solvent.
Toxic and/or fl ammable vapor mixtures!
Risk of poisoning and burns.
Gas mixtures can explode if there is an incompletely filled pump!
Danger to life from flying parts.
Emergency stop
In the case of unforeseen occurrences close the air cut-off valve immediately and open the
return valve (if installed) and/or delivery devices (valves or guns).
Zip52 Finishing
ZIP52 PF Eco-Finishing
ORDER NUMBER DOC 2332848
WARNING
Never reach into the spray jet.
Never point the spray gun at people.
Consult a doctor immediately in the event of skin injuries caused
by paint or solvent. Inform the doctor about the paint or solvent
used.
Never seal defective high pressure parts, instead relieve the
pressure from them and replace them.
WARNING
Operate the unit in a spray booth approved for the working
materials.
-or-
Operate the unit on an appropriate spraying wall with the
ventilation (extraction) switched on.
Observe national and local regulations for the outgoing air
speed.
WARNING
Ensure that the pump and suction system are always completely
filled with cleaning agent or working medium.
Do not spray the unit empty after cleaning.
An air cut-off valve is installed.
An air cut-off valve must be provided by the user.
29

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zip52 pf eco-finishing

Table of Contents