Troubleshooting; Fault - Epever UP1500-M3222 User Manual

Upower series inverter/changer
Hide thumbs Also See for UP1500-M3222:
Table of Contents

Advertisement

5. Troubleshooting

5.1 Fault

Module
Code
BLV
BOV
Battery
BOD
NVE
LTP
OTP
PV
charging
CFA
module
IOV
ILV
Utility
charging
OTP
module
CFA
OVA
IOS
Inverter
OOL
output
module
OTP
CFA
5.2 Troubleshooting
Fault
Battery over voltage
Battery over
discharge
Battery overheating
Device overheating
Output overload
Output short circuit
Fault
Battery over voltage
Battery low voltage
Battery over discharge
Nominal voltage error
Low temperature
over temperature
(PV charge module)
Communication Fault
Alarm
Input over voltage
Input low voltage
over temperature
(Utility charge module)
Communication Fault
Alarm
Input over voltage
Input low voltage
Output voltage
abnormal
Inverter output short
circuit
Output overload
Check if battery voltage too high, and disconnect solar modules.
When the battery voltage is restored to or above LVR point (low
voltage reconnect voltage), the AC load will recover
The inverter/charger will automatically turn the system off. But while
the battery temperature declines to be below overheating recover
temperature value, the inverter/charger will working.
The inverter/charger will automatically turn the system off. But while
the device temperature declines to be below overheating recover
temperature value, the inverter/charger will working.
①Please reduce the number of electric equipments.
②Restart the controller or CFA of setting interface change to ON .
①Check carefully loads connection, clear the fault.
②Restart the controller CFA of setting interface change to ON ..
battery
frame
indicator
blink
Flashing
PV charge
Fast Flashing
Utility
Fast Flashing
inverter
Fast Flashing
Troubleshooting
Fault
Buzzer
indicator
Alarm
On Solid