Chapter 3
GPIB 488.1 Library Reference
Usage Notes
This routine is used to temporarily change the default timeout value assigned to the
device/GPIB Interface board.
The new timeout is used until it is redefined (by calling
re-initialized (by calling
Example
This example changes the timeout (to 30 µs) for all calls specifying the "plotter" device at
PAD 3.
C
Programming Reference Manual
or
); or the system is restarted.
ibfind
ibonl
int plotter;
plotter = ibdev (0,3,0,13,1,0);
ibtmo(plotter, T30us);
3-52
again) the device/board is
ibtmo
GPIB-488