16.6 Lightning Protection
16.7 Overview
Chapter 12 in the main body of this manual contains the requirements for the 150/300 Mbps
Backhaul deployment. This section details the additional requirements for the deployment of
E1/T1.
16.8 Recommended Additional Components for E1/T1 Installation
The recommended components below are in addition to those listed in section 10, the extra
components required for the E1/T1 installation are:
•
Screened (Shielded) Cat 5 Cable
•
Surge Arrestor Units — Transtector type ALPU-ORT, 4 required per link.
www.transtector.com
•
RJ45 screened connectors
•
10 AWG Grounding Cable
For a description of Zone A and Zone B refer to section 10.
Surge Arrestor Unit ALPU-ORT at ODU
Ground (Earth) Cable at Building Entry
Surge Arrestor Unit ALPU-ORT at
Issue 1.1 April 2006
)
Ground (Earth) ODU
Screen Cable
Building Entry
Table 19: Protection Requirements
Zone A
Zone B
Mandatory
Mandatory
Mandatory
Mandatory
Mandatory
Mandatory
Mandatory
Mandatory
Mandatory
Mandatory
Page 157