MODBUS PROTOCOL
Table 2–4: 745 memory map (Sheet 44 of 56)
Addr
Description
20F4
Winding 3 neutral time overcurrent multiplier
20F5
Winding 3 neutral time overcurrent reset
20F6
Winding 3 neutral time overcurrent block
20F7
Winding 3 neutral time overcurrent relays
20F8
Reserved
20FF
Reserved
Winding 1 neutral instantaneous overcurrent 1
2100
Winding 1 neutral instantaneous overcurrent 1 function
2101
Winding 1 neutral instantaneous overcurrent 1 target
2102
Winding 1 neutral instantaneous overcurrent 1 pickup
2103
Winding 1 neutral instantaneous overcurrent 1 delay
2104
Winding 1 neutral instantaneous overcurrent 1 block
2105
Winding 1 neutral instantaneous overcurrent 1 relays
2106
Reserved
210F
Reserved
Winding 2 neutral instantaneous overcurrent 1
2110
Winding 2 neutral instantaneous overcurrent 1 function
2111
Winding 2 neutral instantaneous overcurrent 1 target
2112
Winding 2 neutral instantaneous overcurrent 1 pickup
2113
Winding 2 neutral instantaneous overcurrent 1 delay
2114
Winding 2 neutral instantaneous overcurrent 1 block
2115
Winding 2 neutral instantaneous overcurrent 1 relays
2116
Reserved
211F
Reserved
Winding 3 neutral instantaneous overcurrent 1
2120
Winding 3 neutral instantaneous overcurrent 1 function
2121
Winding 3 neutral instantaneous overcurrent 1 target
2122
Winding 3 neutral instantaneous overcurrent 1 pickup
2123
Winding 3 neutral instantaneous overcurrent 1 delay
2124
Winding 3 neutral instantaneous overcurrent 1 block
2125
Winding 3 neutral instantaneous overcurrent 1 relays
2126
Reserved
212F
Reserved
Winding 1 neutral instantaneous overcurrent 2
2130
Winding 1 neutral instantaneous overcurrent 2 function
2131
Winding 1 neutral instantaneous overcurrent 2 target
2132
Winding 1 neutral instantaneous overcurrent 2 pickup
2133
Winding 1 neutral instantaneous overcurrent 2 delay
2134
Winding 1 neutral instantaneous overcurrent 2 block
2135
Winding 1 neutral instantaneous overcurrent 2 relays
2136
Reserved
213F
Reserved
2–56
Range
Step
0.00 to 100.00
0.01
---
---
---
---
1 to 8
---
---
---
---
---
0.05 to 20.00
0.01
0 to 60000
1
---
---
1 to 8
---
---
---
---
---
0.05 to 20.00
0.01
0 to 60000
1
---
---
1 to 8
---
---
---
---
---
0.05 to 20.00
0.01
0 to 60000
1
---
---
1 to 8
---
---
---
---
---
0.05 to 20.00
0.01
0 to 60000
1
---
---
1 to 8
---
745 TRANSFORMER PROTECTION SYSTEM – COMMUNICATIONS GUIDE
CHAPTER 2: MODBUS PROTOCOL
Units
Format
Default
---
F3
100 = 1.00
---
F68
1 = Linear
---
F87
0 = Disabled
---
F153
None
---
F30
1 = Enabled
---
F46
1 = Latched
× CT
F3
1000=10.00×CT
ms
F1
0 ms
---
F87
0 = Disabled
---
F153
None
---
F30
0 = Disabled
---
F46
1 = Latched
× CT
F3
1000=10.00×CT
ms
F1
0 ms
---
F87
0 = Disabled
---
F153
None
---
F30
0 = Disabled
---
F46
1 = Latched
× CT
F3
1000=10.00×CT
ms
F1
0 ms
---
F87
0 = Disabled
---
F153
None
---
F30
0 = Disabled
---
F46
1 = Latched
× CT
F3
1000=10.00×CT
ms
F1
0 ms
---
F87
0 = Disabled
---
F153
None