MODBUS PROTOCOL
Table 2–4: 745 memory map (Sheet 40 of 56)
Addr
Description
1E41
Fault winding 3 phase A current angle
1E42
Fault winding 3 phase B current magnitude
1E43
Fault winding 3 phase B current angle
1E44
Fault winding 3 phase C current magnitude
1E45
Fault winding 3 phase C current angle
1E46
Fault winding 3 ground current magnitude
1E47
Fault winding 3 ground current angle
1E48
Fault voltage input magnitude
1E49
Fault voltage input angle
1E4A
Fault frequency
1E4B
Reserved
1E4C
Reserved
1FFF
Reserved
Setpoint groups 1 to 4 (addresses 2000 to 3FFF, read/write)
Percent differential
2000
Percent differential function
2001
Percent differential target
2002
Percent differential pickup
2003
Percent differential slope 1
2004
Percent differential break point
2005
Percent differential slope 2
2006
Percent differential block
2007
Percent differential relays
Harmonic inhibit
2008
Harmonic inhibit function
2009
Harmonic inhibit parameters
200A
Harmonic averaging
200B
Harmonic inhibit level
200C
Reserved
Energization inhibit
200D
Energization inhibit function
200E
Energization inhibit parameters
200F
Energization inhibit harmonic averaging
2010
Energization inhibit level
2011
Energization inhibit duration
2012
Energization sensing by current
2013
Minimum energization current
2014
Energization sensing by voltage
2015
Minimum energization voltage
2016
Breakers are open signal
2017
Parallel transformer breaker close signal
2018
Reserved
Fifth harmonic inhibit
2019
Fifth harmonic inhibit function
201A
Fifth harmonic averaging
201B
Fifth harmonic inhibit level
2–52
Range
Step
0 to 359
1
0.0 to 40.0
0.1
0 to 359
1
0.0 to 40.0
0.1
0 to 359
1
0.0 to 40.0
0.1
0 to 359
1
0.0 to 2.0
0.1
0 to 359
1
45.00 to 60.00
0.01
---
---
---
---
0.05 to 1.00
0.01
15 to 100
1
1.0 to 20.0
0.1
50 to 100
1
---
---
1 to 8
---
---
---
---
---
---
---
0.1 to 65.0
0.1
---
---
---
---
---
---
0.1 to 65.0
0.1
0.05 to 600.00
0.01
---
---
0.10 to 0.50
0.01
---
---
0.50 to 0.99
0.01
---
---
---
---
---
---
---
---
0.1 to 65.0
0.1
745 TRANSFORMER PROTECTION SYSTEM – COMMUNICATIONS GUIDE
CHAPTER 2: MODBUS PROTOCOL
Units
Format
Default
° Lag
F1
330° Lag
× CT
10 = 1.0 × CT
F2
° Lag
F1
90° Lag
× CT
F2
10 = 1.0 × CT
° Lag
F1
210° Lag
× CT
F2
0.0 × CT
° Lag
F1
0° Lag
× VT
F2
10 = 1.0 × VT
° Lag
F1
0° Lag
Hz
F3
60.00 Hz
---
F30
1 = Enabled
---
F46
1 = Latched
× CT
F3
30 = 0.30 × CT
%
F1
25%
× CT
20 = 2.0 × CT
F2
%
F1
100%
---
F87
0 = Disabled
---
F153
None
---
F30
1 = Enabled
---
F64
0 = 2nd
---
F30
0 = Disabled
% ƒo
F2
200 = 20.0% ƒo
---
F30
1 = Enabled
---
F64
0 = 2nd
---
F30
1 = Enabled
% ƒo
F2
200 = 20.0% ƒo
s
F1
10 = 0.10 s
---
F30
1 = Enabled
× CT
F3
10 = 0.10 × CT
---
F30
0 = Disabled
× VT
85 = 0.85 × VT
F3
---
F88
0 = Disabled
---
F88
0 = Disabled
---
F30
0 = Disabled
---
F30
0 = Disabled
% ƒo
F2
100 = 10.0% ƒo