Implementation Table - GE Multilin 745 Communications Manual

Transformer protection system
Table of Contents

Advertisement

DNP PROTOCOL

Implementation table

3–2
DNP 3.0: DEVICE PROFILE DOCUMENT (Continued)
Timeouts while waiting for:
Data Link Confirm
Complete Appl. Fragment
Application Confirm
(fixed value is 5000 milliseconds
Complete Appl. Response
Others (None)
Executes Control Operations:
Write Binary Outputs
Select/Operate
Direct Operate
Direct Operate: No Ack
Count > 1
Pulse On
Pulse Off
Latch On
Latch Off
Trip/Close
See Binary output / control relay output block on page 3–4 for explanation of above.
Queue
Clear Queue
Reports Binary Input Change Events when no
specific variations requested:
Ë
Never
Ë
Only time-tagged

Ë
Only non-time-tagged
Ë
Configurable to send both, one or the
other
Sends Unsolicited Responses:
Ë
Never

Ë
Configurable
Ë
Only certain objects
Ë
Sometimes
Ë
ENABLE/DISABLE UNSOLICITED
Function codes supported
Default Counter Object/Variation:
Ë
No Counters Reported

Ë
Configurable
Ë
Default Object / Default Variation
Ë
Point-by-point list attached
Sends Multi-Fragment Responses:
Table notes:
1.
The data link layer confirmation mode, confirmation timeout, and number of retries
are all configurable. Refer to the 745 instruction manual for further details.
The following table gives a list of all objects recognized and returned by the relay.
Additional information is provided on the following pages including a list of the default
variations returned for each object and lists of defined point numbers for each object.
Implementation table notes:
1.
For this object, the quantity specified in the request must be exactly 1 as there is only
one instance of this object defined in the relay.
2.
All static input data known to the relay is returned in response to a request for Class 0.
This includes all objects of type 1 (binary input), type 10 (binary output) and type 30
(analog input).
3.
The point tables for binary input and analog input objects contain a field which
defines to which event class the corresponding static data has been assigned.
4.
For this object, the qualifier code must specify an index of 7 only.
Ë
None
Ë
Fixed
Ë
Ë
None
Fixed

Ë
None
Ë
Fixed

Ë
Ë
None
Fixed

Ë
Never
Ë
Always

Ë
Never
Ë
Always

Ë
Never
Ë
Always

Ë
Never
Ë
Always

Ë
Never
Ë
Always

Ë
Never
Ë
Always
Ë
Never
Ë
Always

Ë
Never
Ë
Always
Ë
Never
Ë
Always
Ë
Never
Ë
Always
Ë
Never
Ë
Always

Ë
Never
Ë
Always

Reports time-tagged Binary Input Change
Events when no specific variation requested:
Ë
Never
Ë
Binary Input Change With Time

Ë
Binary Input Change With Relative Time
Ë
Configurable
Sends Static Data in Unsolicited Responses:
Ë
Never

Ë
When Device Restarts
Ë
When Status Flags Change
Counters Roll Over at:
Ë
No Counters Reported

Ë
Configurable
Ë
16 Bits
Ë
32 Bits
Ë
Other Value
Ë
Point-by-point list attached
Ë
Yes
Ë
No

745 TRANSFORMER PROTECTION SYSTEM – COMMUNICATIONS GUIDE
CHAPTER 3: DNP PROTOCOL
Ë
Variable
Ë
Configurable

Ë
Ë
Variable
Configurable
Ë
Variable
Ë
Configurable
Ë
Ë
Variable
Configurable
Ë
Sometimes
Ë
Configurable
Ë
Sometimes
Ë
Configurable
Ë
Sometimes
Ë
Configurable
Ë
Sometimes
Ë
Configurable
Ë
Sometimes
Ë
Configurable
Ë
Sometimes
Ë
Configurable

Ë
Sometimes
Ë
Configurable
Ë
Sometimes
Ë
Configurable

Ë
Sometimes
Ë
Configurable

Ë
Sometimes
Ë
Configurable

Ë
Sometimes
Ë
Configurable
Ë
Sometimes
Ë
Configurable