GE Multilin 745 Communications Manual page 39

Transformer protection system
Table of Contents

Advertisement

CHAPTER 2: MODBUS PROTOCOL
Table 2–4: 745 memory map (Sheet 21 of 56)
Addr
Description
0817
Maximum event winding 2 ground current
0818
Maximum event winding 3 phase A current
0819
Maximum event winding 3 phase B current
081A
Maximum event winding 3 phase C current
081B
Maximum event winding 3 ground current
081C
Reserved
081D
Reserved
082F
Reserved
Event recorder data
0830
Event XX date of event (2 registers)
0832
Event XX time of event (2 registers)
0834
Event XX cause of event
0835
Event XX winding 1 phase A current magnitude
0836
Event XX winding 1 phase A current angle
0837
Event XX winding 1 phase B current magnitude
0838
Event XX winding 1 phase B current angle
0839
Event XX winding 1 phase C current magnitude
083A
Event XX winding 1 phase C current angle
083B
Event XX winding 1 ground current magnitude
083C
Event XX winding 1 ground current angle
083D
Event XX winding 1 phase A 2nd harmonic
083E
Event XX winding 1 phase B 2nd harmonic
083F
Event XX winding 1 phase C 2nd harmonic
0840
Event XX winding 1 phase A 5th harmonic
0841
Event XX winding 1 phase B 5th harmonic
0842
Event XX winding 1 phase C 5th harmonic
0843
Event XX winding 2 phase A current magnitude
0844
Event XX winding 2 phase A current angle
0845
Event XX winding 2 phase B current magnitude
0846
Event XX winding 2 phase B current angle
0847
Event XX winding 2 phase C current magnitude
0848
Event XX winding 2 phase C current angle
0849
Event XX winding 2 ground current magnitude
084A
Event XX winding 2 ground current angle
084B
Event XX winding 2 phase A 2nd harmonic
084C
Event XX winding 2 phase B 2nd harmonic
084D
Event XX winding 2 phase C 2nd harmonic
084E
Event XX winding 2 phase A 5th harmonic
084F
Event XX winding 2 phase B 5th harmonic
0850
Event XX winding 2 phase C 5th harmonic
0851
Event XX winding 3 phase A current magnitude
0852
Event XX winding 3 phase A current angle
0853
Event XX winding 3 phase B current magnitude
0854
Event XX winding 3 phase B current angle
0855
Event XX winding 3 phase C current magnitude
0856
Event XX winding 3 phase C current angle
745 TRANSFORMER PROTECTION SYSTEM – COMMUNICATIONS GUIDE
Range
Step
Units
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
0
---
° Lag
---
---
0 to 359
1
° Lag
---
---
0 to 359
1
° Lag
---
---
0 to 359
1
° Lag
0.0 to 99.9
0.1
% ƒo
0.0 to 99.9
0.1
% ƒo
0.0 to 99.9
0.1
% ƒo
0.0 to 99.9
0.1
% ƒo
0.0 to 99.9
0.1
% ƒo
0.0 to 99.9
0.1
% ƒo
---
---
0 to 359
1
° Lag
---
---
0 to 359
1
° Lag
---
---
0 to 359
1
° Lag
---
---
0 to 359
1
° Lag
0.0 to 99.9
0.1
% ƒo
0.0 to 99.9
0.1
% ƒo
0.0 to 99.9
0.1
% ƒo
0.0 to 99.9
0.1
% ƒo
0.0 to 99.9
0.1
% ƒo
0.0 to 99.9
0.1
% ƒo
---
---
0 to 359
1
° Lag
---
---
0 to 359
1
° Lag
---
---
0 to 359
1
° Lag
MODBUS PROTOCOL
Format
Default
A
F82
0 A
A
F80
0 A
A
F80
0 A
A
F80
0 A
A
F83
0 A
F23
---
F22
---
F24
---
A
F78
0 A
F1
0° Lag
A
F78
0 A
F1
0° Lag
A
F78
0 A
F1
0° Lag
A
F81
0 A
F1
0° Lag
F2
0% ƒo
F2
0% ƒo
F2
0% ƒo
F2
0% ƒo
F2
0% ƒo
F2
0% ƒo
A
F79
0 A
F1
0° Lag
A
F79
0 A
F1
0° Lag
A
F79
0 A
F1
0° Lag
A
F82
0 A
F1
0° Lag
F2
0% ƒo
F2
0% ƒo
F2
0% ƒo
F2
0% ƒo
F2
0% ƒo
F2
0% ƒo
A
F80
0 A
F1
0° Lag
A
F80
0 A
F1
0° Lag
A
F80
0 A
F1
0° Lag
2–33