Chapter 3. Operation; Power On - Initial Setting - Power Off; Power On - JRC JUE-87 Instruction Manual

Inmarsat-c mobile earth station (egc receiver)
Hide thumbs Also See for JUE-87:
Table of Contents

Advertisement

3.1 Power ON - Initial setting - Power OFF

Before turning on all power switches of JUE-87, confirm that all the signal cables and
power cables are connected correctly.

3.1.1 Power ON

When the power switch of IME is turned on, JUE-87 synchronizes with NCS TDM career(*).
Step
Operation/Response (Example)
1
・ Turn on the DC switch and AC switch on the
EXT PSU.
・ Turn on the IME and the POWER LED of
the IME is illuminated.
・ The software version is displayed and
operation check.
2
・The IME system software starts up in about
30 seconds, then Main menu screen is
displayed.
3
・Confirming that EME and IME (DTE unit) are
compatible with model.
(To close this window, press F10 key.)
If EME and IME (DTE unit) are not compatible
with model, please inform JRC.
4
・ Turn on the printer.
・ The status is changed "Log-out" or
"Egc-only" to "Tune" in the first line on the
main menu, then JUE-87 is started selecting
NCS common channel.
5
・ After few minutes, the status is changed Tune
to "Log-out" or "Egc-only" in the first line on
the main menu.
6
・ Set up each parameter following
"3.1.3 Initial setting".
* NCS TDM carrier: The signal outputted from NCS as COMMON channel.

CHAPTER 3. OPERATION

NOTE
3-1
Screen (Example)
NOW LOADING・・・
SELF DIAGNOSING・・・
Software version
ROM check
RAM check
Keyboard check
---Model & Country mode Compatibility---
EME and DTE are compatible with
model & country mode.
Country mode: Standard
3
:1.00
:OK
:OK
:OK
F10:Previous