JRC JFC-180BB Instruction Manual
JRC JFC-180BB Instruction Manual

JRC JFC-180BB Instruction Manual

Echo sounder
Hide thumbs Also See for JFC-180BB:
Table of Contents

Advertisement

Quick Links

JFC-180BB
Echo Sounder
Instruction Manual
< Advanced >
Echo Adjust/Display Setup
Alarm
NAV Operation
Image List
System Setting
CCD Camera
Data of SD Card and USB Memory
INDEX
1
2
3
4
5
6
7
8

Advertisement

Table of Contents
loading

Summary of Contents for JRC JFC-180BB

  • Page 1 Echo Adjust/Display Setup Alarm NAV Operation Image List System Setting CCD Camera JFC-180BB Data of SD Card and USB Memory INDEX Echo Sounder Instruction Manual < Advanced >...
  • Page 3 Cautions for High Voltage High voltages, ranging from several hundreds to tens of thousands of volts, are used in electronic apparatus, such as radio and radar instruments. These voltages are totally harmless in most operations. However, touching a component inside the unit is very dangerous.
  • Page 4 Precautions for Rescue of Victim of Electric Shock When a victim of electric shock is found, turn off the power source and ground the circuit immediately. If this is impossible, move the victim away from the unit as quick as possible without touching him or her with bare hands.
  • Page 5 Method of First-Aid Treatment Precautions for First-Aid Treatments Whenever a person is struck by an electrical shock, give the patient artificial respiration immediately on the spot, unless it is absolutely necessary to move the patient for safety's sake. Once started, artificial respiration should be continued rhythmically. (1) Refrain from touching the patient carelessly as a result of the accident;...
  • Page 6  Treatment to Give When the Patient Has a Pulse Beating but Has Ceased to Breathe ∗ Performing mouth-to-mouth artificial respiration - Fig. 1 (1) Bend the patient's face backward until it is directed to look back. (A pillow may be placed under the neck.) (2) Pull up the lower jaw to open up the airway.
  • Page 7 (3) Blowing air into the patient's lungs. Blow air into the patient's lungs until chest is seen to rise. The first 10 breaths must be blown as fast as possible. Fig. 1 Mouth-to-mouth artificial respiration  Treatment to Give When the Patient Has No Pulse Beating and Has Ceased to Breathe ∗...
  • Page 8 Fig. 2 Cardiac massage 7ZPNA4619A...
  • Page 9 Procedure for cardiopulmonary resuscitation (CPR) using the AED (Automated External Defibrillator) A person is collapsing. A person is collapsing. - Secure the safety of the surrounding area. - Secure the safety of the surrounding area. - Prevent secondary disasters. - Prevent secondary disasters. Listen to the appeal of the Responding Check for response.
  • Page 10 Procedure for Cardiopulmonary Resuscitation (CPR) Using the AED (Automated External Defibrillator) 1. Check the scene for safety to prevent secondary disasters Are you OK? a) Do not touch the injured or ill person in panic when an accident has occurred. (Doing so may cause electric shock to the first-aiders.) b) Do not panic and be sure to turn off the power.
  • Page 11 6. Check for breathing a) After opening the airway, check quickly for breathing for no more than 10 seconds. Put your cheek down by the mouth and nose area of the injured or ill person, look at his/her chest and abdomen, and check the following three points.
  • Page 12 8. Cardiopulmonary resuscitation (CPR) (combination of chest compressions and rescue breaths) a) Chest compressions 1) Position of chest compressions • Position the heel of one hand in the center of the chest, approximately between the nipples, and place your other hand on top of the one that is in position. 2) Perform chest compressions Compress with these...
  • Page 13 9. When to stop cardiopulmonary resuscitation (CPR) a) When the injured or ill person has been handed over to the emergency services b) When the injured or ill person has started moaning or breathing normally, lay him/her on his/her side in a recovery position and wait for the arrival of emergency services. 10....
  • Page 14 12. Electrocardiogram analysis a) The AED automatically analyzes electrocardiograms. Follow the voice prompts of the AED and ensure that nobody is touching the injured or ill person while you are operating the AED. b) On some AED models, you may need to push a button to analyze the heart rhythm.
  • Page 15 16. When to stop CPR (Keep the electrode pads on.) a) When the injured or ill person has been handed over to the emergency services b) When the injured or ill person has started moaning or breathing normally, lay him/her on his/her side in a recovery position and wait for the arrival of emergency services.
  • Page 16: Preface

    • JRC is not liable for any damages caused by earthquake, lightning, wind and flood damage and fire for which JRC is not responsible, and actions by third parties, other accidents, customer’s unintended error/abuse and the use under other abnormal conditions.
  • Page 17: Before Operation

    JFC-180BB Before Operation Before Operation Pictorial Indication Various pictorial indications are included in this instruction manual and are shown on this equipment so that you can operate them safely and correctly and prevent any danger to you and / or to other persons and any damage to your property during operation.
  • Page 18: Precautions Upon Equipment Operation

    Before Operation JFC-180BB Precautions upon Equipment Operation DANGER Cautions on handling In case of smoke or fire, boat power off and the power of this unit. It may cause fire, electric shock or damage. Be cautious of remaining high voltage.
  • Page 19 JFC-180BB Before Operation Cautions on handling The information displayed in this unit is not provided directly for your navigation. For your navigation, be sure to see the specified material. Use the specified fuse. If un-specified fuse is used, it may cause a fire, smoke or damage.
  • Page 20: Table Of Contents

    Contents JFC-180BB Contents Caution ..............................i PREFACE .............................. xiv Before Operation ............................ xv Pictorial Indication ..................................xv Examples of Pictorial Indication ............................. xv Warning Label ....................................xv Precautions upon Equipment Operation .......................... xvi Contents .............................. xviii Chapter 1 Echo Adjust/Display Setup ..................1-1 1.1 Introduction .............................
  • Page 21 JFC-180BB Contents 1.12 Changing of W. Temp. Font size ....................1-19 1.13 Displaying of Speed Value/Not to display ................... 1-20 1.14 Display of Detection Area/Not to display ..................1-20 1.15 Widening of Bottom Search Range .................... 1-21 1.16 Selection of a Sounding Source (frequency) ................1-21 1.17 Setting depth to perform Bottom Limit searching at Auto-Range / Auto-Shift ......
  • Page 22 Contents JFC-180BB 3.6.2 Selection of types of NAV Display ......................3-4 3.7 Storage of waypoint data ........................ 3-6 3.8 Recall of waypoint data........................3-7 Chapter 4 Image List .......................... 4-1 4.1 Recall of Image ..........................4-1 4.2 Editing of Image Comment ......................4-2 4.3 Deleting of Image ..........................
  • Page 23 JFC-180BB Contents 5.14.4 Setup of frequency and beam angle for HF 2 transducer ......... 5-11 5.14.5 Setup of frequency and beam angle for LF 1 transducer .......... 5-11 5.14.6 Setup of frequency and beam angle for LF 2 transducer .......... 5-11 5.14.7 Setup of Bottom Limit HF ........................
  • Page 24 Contents JFC-180BB 6.1.3 Zoom/Reduce of CCD camera images ....................6-2 Chapter 7 Data of SD Card and USB Memory ..............7-1 7.1 Storage ............................7-1 7.2 Recall .............................. 7-1 7.3 SD Card recommendation ......................7-1 7.4 USB Memory recommendation ...................... 7-1 Chapter 8 INDEX ...........................
  • Page 25: Chapter 1 Echo Adjust/Display Setup

    Chapter 1 Echo Adjust/Display Setup 1.1 Introduction JFC-180BB is the Black Box type without the display unit, for which customer can select the display monitor of preference. The external monitor and connecting cable are user supply. This unit equipped with the latest digital process can accurately display circumstances in the water under all conditions.
  • Page 26: Menu List

    Chapter 1 Echo Adjust/Display Setup JFC-180BB 1.3 Menu List The factory deafult setting is shown in bold and underlined. 1. [SHIFT/ M OFF] key Shift OFF (OFF, ON) Range Mode (Auto range, Manual, Auto shift) 2. [NORMAL/ZOOM] key Normal/Zoom (Normal range operation, Zoom range operation) 3.
  • Page 27 JFC-180BB Chapter 1 Echo Adjust/Display Setup 11. [MENU] key Echo Adjust IR (OFF, Low, High) Random Transmission (OFF, 1, 2) Color Erase (0 ~ 50 %, 0 %) Noise Reduction (0~10: 0) TX Power (HF) (20, 30, 40, 50, 60, 70, 80, 90, 100, Auto)
  • Page 28 Chapter 1 Echo Adjust/Display Setup JFC-180BB Disp. Setup2 Scale (OFF, ON) Scale Position (Side, Center) Scale Value (Small, Medium, Large) Color Bar Scale (OFF, ON) Image Title (Frequency, HF1 LF1) Water Temp Window (OFF, 5 minutes, 10 minutes, 15 minutes, 30 minutes, 60 minutes) W.
  • Page 29 JFC-180BB Chapter 1 Echo Adjust/Display Setup Alarm1 Bottom Alarm (OFF, ON) Upper depth (0 ~ Lower depth -1 m: 5 m) Lower depth (Upper depth ~ 3000 m: 50 m) Fish Alarm (OFF, ON) Fish From (0.0 ~ 3000 m: 5 m) Fish Span (1.0 ~ 3000 m: 50 m)
  • Page 30 Chapter 1 Echo Adjust/Display Setup JFC-180BB 12. [SUB MENU] key Event Key Usage (Store Position, Store Image, Homing) System (Shift Digit Input, IR (F2), Color Erase, Noise Reduction, Background Color, TVG Adjust, White FUNC1.Key Setting Line, A Scope, Image Swap, Image Title (F1), VRM Interval, Sona-tone, Nav Start, Image Recall, FUNC2.Key Setting...
  • Page 31 JFC-180BB Chapter 1 Echo Adjust/Display Setup Heaving Heaving (OFF, ON) HF TD Back and Forth (- 100.0 ~ 100.0: 0.0) HF TD Right and Left (- 100.0 ~ 100.0: 0.0) HF TD Height (- 100.0 ~ 100.0: 0.0) LF TD Back and Forth (- 100.0 ~ 100.0: 0.0) LF TD Right and Left (- 100.0 ~ 100.0: 0.0)
  • Page 32 Chapter 1 Echo Adjust/Display Setup JFC-180BB Maintain Simulation (OFF, ON) Simulation Select (Shallow Depth, Intermediate*, Deep Depth*) (*It is necessary to store the simulation data in the internal memory.) Key Lock (OFF, ON) Initialize (CM1, CM2, CM3, CM4, CM5, CM6, System All)
  • Page 33: Change Of Tx Power

    JFC-180BB Chapter 1 Echo Adjust/Display Setup 4. Press [▲] and [▼] and select TX Power. The smaller the value is, the weaker the TX Power becomes. 1.4 Change of TX Power 5. Press to close the menu. The strength of TX Power (transmission output) can be changed.
  • Page 34: Change Of Dynamic Range Of Echo

    Chapter 1 Echo Adjust/Display Setup JFC-180BB 1.5 Change of dynamic range of Echo 1.6.1 Changing of TVG Type Echo Adjust - Dynamic Range* HF1, HF2, TVG* - TVG Type LF1, LF2 TVG is a function to display images, by The dynamic range of reflected signal (color correcting the attenuation of ultrasonic gradation) can be adjusted.
  • Page 35: Changing Of Tvg Strength

    JFC-180BB Chapter 1 Echo Adjust/Display Setup The setup box of [TVG Depth XX] will be 1.6.2 Changing of TVG Strength displayed. TVG - TVG Strength HF1, HF2, LF1, LF2 The gradient of gain variation is adjusted to reduce gain for shallower depth.
  • Page 36: Displaying Of A Scope

    Chapter 1 Echo Adjust/Display Setup JFC-180BB When the value is larger, the correction The setup box of [A Scope] will be reference depth becomes deeper and the displayed. gain at shallower depth will be reduced when smaller. 5. Press to close the menu.
  • Page 37: Changing Of Screen

    JFC-180BB Chapter 1 Echo Adjust/Display Setup 4. Press [▲] and [▼] and select the line width of white line. At 1, the finest line will be displayed and at 5, the thickest line will be displayed. At [Auto], the width of white line will vary depending on the strength of reflection from sea bottom.
  • Page 38: To Display Of Scale/Not To Display

    Chapter 1 Echo Adjust/Display Setup JFC-180BB The setup box of [Color Tone] will be 3. Press [ displayed. ] of The setup box of [Scale Position] will be displayed. 4. Press [▲] and [▼] to set the color tone to which changed.
  • Page 39: Set The Image Title As Frequency/ Hfx Lfx

    JFC-180BB Chapter 1 Echo Adjust/Display Setup 1.9.8 Changing of Image Direction 3. Press [ ] of Disp. Setup1 - Image Direction The scroll direction of displayed images can The setup box of [Color Bar Scale] will be changed. be displayed.
  • Page 40: Detailed Display Of Image Resolution And Lapse Time

    Chapter 1 Echo Adjust/Display Setup JFC-180BB Example of display: 4. With [▲] and [▼] keys, select swapping type [A|B] or [B|A] . When [A|B] is selected, the alignment of images will be HF1, HF2, LF1 and LF2 from the right side. When [B|A] is selected, the alignment will be HF1, HF2, LF1, and LF2 from the left side.
  • Page 41: Zoom Image Split

    JFC-180BB Chapter 1 Echo Adjust/Display Setup Example of display: 4. With [▲] and [▼] keys, select one of the widths of zoomed display image, [Wide], In case of two normal images are selected [Medium] or [Narrow]. 5. Press to close the menu.
  • Page 42: Changing Of W. Temp. Graph Range

    Chapter 1 Echo Adjust/Display Setup JFC-180BB 1.10.1 Display Water Temp The setup box of [W. Temp. Graph Window/Not to display Range] will be displayed. Disp. Setup2 - Water Temp Window The latest water temperature and the transition of water temperature in the past can be displayed in a graph.
  • Page 43: Changing Of Display Position Of Depth

    JFC-180BB Chapter 1 Echo Adjust/Display Setup Example of display: The setup box of [Depth Font Size] will be displayed. 4. With [▲] and [▼] keys, select one of Top display Bottom of Depth Font Size, [Small], [Medium] or position display [Large].
  • Page 44: Displaying Of Speed Value/Not To Display

    Chapter 1 Echo Adjust/Display Setup JFC-180BB 1. Press 2. Select [Disp. Setup2] - [W. Temp. Font size]. 4. With [▲] and [▼] keys, select [ON] to 3. Press [ ] of display and [OFF] to stop. 5. Press to close the menu.
  • Page 45: Widening Of Bottom Search Range

    1. Press 2. Select [BTM Search] - [Sounding Source]. 3. Press [ ] of Broaband Type Transducer: A transducer that can handle multiple frequencies (having wide range of frequency bandwidth). CFT-5052, CFT-5062 can be connected to JFC-180BB. 付録 7ZPNA4619A 1-21...
  • Page 46: Setting Depth To Perform Bottom Limit Searching At Auto-Range / Auto-Shift

    Chapter 1 Echo Adjust/Display Setup JFC-180BB The setup box of [Sounding Source] will 4. Pressing [▲], [▼], [ ] or [ ], set a depth. be displayed. Larger value makes the time longer for detecting the sea bottom again after lost due to bubble etc..
  • Page 47: Selecting Range Operation (Per Image/Whole Screen At Same Time)

    JFC-180BB Chapter 1 Echo Adjust/Display Setup 1.19 Selecting Range Operation (per image/Whole screen at same time) Range Setup - Range Operation It can be selected whether the range operation is changed for all images at once or for each image.
  • Page 48 Chapter 1 Echo Adjust/Display Setup JFC-180BB 1-24 7ZPNA4619A...
  • Page 49: Chapter 2 Alarm

    JFC-180BB Chapter 2 Alarm 6. Press to close the menu. Chapter 2 Alarm Caution: Press any key stop any 2.1 Use of Bottom Alarm alarm sound and alarm display.. When the detected position of sea bottom is shallower than the upper limit or deeper than...
  • Page 50: Setup Of Lower Depth

    Chapter 2 Alarm JFC-180BB 2.1.3 Setup of Lower Depth 2.2.1 Start/Stop Fish Alarm Alarm1 - Lower Depth Alarm1 - Fish Alarm To set the depth, where to activate alarm Select [ON] to enable the fish alarm and when the depth becomes deeper than a [OFF] to deactivate.
  • Page 51: Setup Of Fish From

    JFC-180BB Chapter 2 Alarm Caution: When CCD camera 3. Press [ ] of image is displayed, the alarm display will be only by icon display. (See “2.7 Confirmation The setup box of [Fish Span] will be of alarm conditions”, p 2-9.) displayed.
  • Page 52: Setup Of Lower Level

    Chapter 2 Alarm JFC-180BB where warning is activated together with 2.2.6 Setup of Alarm Signal Length the preset value of the [Lower Level]. Alarm1 - Alarm Signal Length 5. To set the Fish Alarm related items This is to set the signal length of fish schools subsequently: to sound the fish school alarm.
  • Page 53: Use Water Temp Alarm

    JFC-180BB Chapter 2 Alarm The setup box of [Fish Image] will be 4. Press [▲] and [▼] keys, to select [ON] to displayed. activate the alarm and [OFF] to deactivate. At [ON-Inside range], alarm is delivered when entering the preset range.
  • Page 54: Setup Of Lower Temp Alarm

    Chapter 2 Alarm JFC-180BB The setup box of [Upper Temp Alarm] will Caution: The maximum water be displayed. temperature at lower side of the alarm range cannot be set larger than the temperature at upper side of the temperature alarm.
  • Page 55: Setup Of Speed Limit

    JFC-180BB Chapter 2 Alarm 2.5 Use the alarm at waypoint navigation At [ON-Slower], alarm is delivered when the speed falls less than the specified Alarm can be used while waypoints are set. speed. (See the Instruction Manual [Basic], “4.4 To 5.
  • Page 56: Sound Alarm When Xte To Waypoint Has Been Found

    Chapter 2 Alarm JFC-180BB 6. Press to close the menu. Caution: Press any key to stop any alarm sound and alarm display. Caution: Press any key to stop any alarm sound and alarm display. Caution: To activate the alarm sound and the alarm display...
  • Page 57: Voltage Alarm

    JFC-180BB Chapter 2 Alarm The icons for alarm represent as follow: Caution: The alarm setup range for [Arrival Alarm] and [XTE Alarm] cannot set individually. Bottom Alarm 2.6 Voltage Alarm Fish Alarm The input voltage to this equipment is continuously monitored, and alarm sound...
  • Page 58 Chapter 2 Alarm JFC-180BB 2-10 7ZPNA4619A...
  • Page 59: Chapter 3 Nav Operation

    JFC-180BB Chapter 3 NAV Operation The setup box of [NAV Start] will be Chapter 3 NAV Operation displayed. 3.1 Starting waypoint NAV NAV - NAV Start By selecting a waypoint from the waypoint list, waypoint NAV can be started. 6. Pressing [▲] and [▼] keys, select [Yes] to To start waypoint NAV, registration of start and [No] not to start.
  • Page 60: Editing Of Waypoint

    Chapter 3 NAV Operation JFC-180BB The setup box of [NAV Cancel] will be Caution: The selected list No. will displayed. turn yellow. 4. Using of [▲] and [▼] keys, select No. of list to be edited. 5. Press 6. Select characters with [▲] and [▼] keys.
  • Page 61: Deletion Of All Waypoints In The Waypoints List

    JFC-180BB Chapter 3 NAV Operation The [WPT Delete] list box will be displayed. 3. Press [ ] of The setup box of [All WPTs:DLT] will be displayed. Caution: The list No. selected will 4. When all waypoints are to be deleted, turn yellow.
  • Page 62: Selection Of Nav Display

    Chapter 3 NAV Operation JFC-180BB Example of display: When [NAV1] is selected, the NAV screen in the configuration registered by NAV1 will be displayed. When [NAV2] is selected, the NAV screen Compass in the configuration registered by NAV2 (For 2 display areas) will be displayed.
  • Page 63 JFC-180BB Chapter 3 NAV Operation “Compass” displays own boat course in The setup box of [NAV Display1 Select] will be displayed. upward direction and wind direction with an arrow. In addition, during waypoint navigation, a flag will be displayed at the waypoint direction.
  • Page 64: Storage Of Waypoint Data

    Chapter 3 NAV Operation JFC-180BB selected, the setup box of [NAV Display3 or “HDG” displays the ship’s bearing in numerical value at input. Display4 Select] will be displayed. “XTE” displays the deviated distance from To select the display area again, press the course line to a waypoint in numerical value during waypoint navigation.
  • Page 65: Recall Of Waypoint Data

    JFC-180BB Chapter 3 NAV Operation The [Data Reading] selection list box will be displayed. (When SD card is selected) 4. Using [▲] and [▼] keys, select [SD Card] or [USB Memory] to be recalled. (When USB memory is selected) 5. Press [ ] of 6.
  • Page 66 Chapter 3 NAV Operation JFC-180BB 7ZPNA4619A...
  • Page 67: Chapter 4 Image List

    JFC-180BB Chapter 4 Image List 5. To search by comments, use [▲] and [▼] Chapter 4 Image List keys and select [Comment Search]. 4.1 Recall of Image To search by dates, select [Date Search]. To search by the items without dates, Image - Image Recall select [No Date Search].
  • Page 68: Editing Of Image Comment

    Chapter 4 Image List JFC-180BB Select characters with [▲] and [▼]. The recalling function of images will be (Characters: 0 ~ 9). ended. Using [◄] or [►] key, move the position of The waypoint is set, and the waypoint characters highlighted in reverse.
  • Page 69 JFC-180BB Chapter 4 Image List The setup box of [Image List Search] will 8. The setup box of [Date Search] will be be displayed. displayed. Select characters with [▲] and [▼]. (Characters: 0 ~ 9). 5. To search by comments, select [Comment Search] using [▲] and [▼] keys.
  • Page 70: Deleting Of Image

    Chapter 4 Image List JFC-180BB 13. To end editing, press Caution: The list No. selected will turn yellow. 14. After completion of editing, press 4. A short list of images can be made after search. The setup box of [Edit End] will be displayed.
  • Page 71: Deletion Of All The Images In The Image List

    JFC-180BB Chapter 4 Image List 4.4 Deletion of all the images in the Image 3. Press [ ] of List Maintain - All IMG DT:DLT The [Data Writing] selection list box will be This is the function to delete all images displayed.
  • Page 72 Chapter 4 Image List JFC-180BB 1. Press 2. Select [Image] - [Data Reading]. 3. Press [ ] of The [Data Reading] selection list box will be displayed. 4. Using [▲] and [▼] keys, select [SD Card] or [USB Memory] to be recalled.
  • Page 73: Chapter 5 System Setting

    JFC-180BB Chapter 5 System Setting Chapter 5 System Setting 5.1.1 Setup of [F1] key System - FUNC1.Key Setting 5.1 Allocation of function keys (F1/F2) to The functions to be allocated to [F1] key aimed operation shall be selected. The operability can be improved, by 1.
  • Page 74: Setup Of [F2] Key

    Chapter 5 System Setting JFC-180BB 5.1.2 Setup of [F2] key 3. Press [►] of System - FUNC2.Key Setting The functions to be allocated to [F2] key The setup box of [Guide Window] will be shall be selected. displayed. 1. Press 4.
  • Page 75: Limitation Of Menu To Be Changed

    JFC-180BB Chapter 5 System Setting 5.4 Limitation of Menu to be changed The setup box of [Bubble] will be displayed. System - Simple Menu 4. Select the degree of reduction in bubbling This is the function to turn the menu items, frequency, using [▲] and ▼] keys.
  • Page 76: Changing Of Water Temp Source

    Chapter 5 System Setting JFC-180BB [NMEA] uses input values from external sources connected to J3 and J8 connectors. (As for the connection to J6, J3 and J8 connectors, see the Installation Manual, “1.9.1 Connection of cables to Display and Processor unit”.) 5.
  • Page 77: No Received Sync

    JFC-180BB Chapter 5 System Setting 1. Press 3. Press [►] of 2. Select [Source] - [EXT Trigger Type]. The setup box of [No received Sync] will 3. Press [ ] of be displayed. The setup box of [EXT Trigger Type] will be displayed.
  • Page 78: Correction

    Chapter 5 System Setting JFC-180BB 5. Press to close the menu. 1. Press 2. Select [Correct] - [Sonic Speed]. 5.12 Correction 3. Press [ ►] of [Correct] is provided to correct errors in various data input to this equipment and to The setup box of [Sonic Speed] will be improve the application environment.
  • Page 79: Adjustment Of Transducer's Gain

    JFC-180BB Chapter 5 System Setting When the setup of [Speed Source] is When a red square mark appears at right [NMEA], the correction will be performed side upper corner of the Gain (TD) setup in value. (Setup range: - 10.0 ~ 10.0) box, the red lighted gain knob shall be operated.
  • Page 80: Use Of Heaving

    Chapter 5 System Setting JFC-180BB Example of display: 5. Press to close the menu. 5.13 Use of Heaving This is the function to control the seesaw movement of images by detecting the seesaw movement caused by wave by sensors, when the images of sea bottom...
  • Page 81: Setup Of Transducer

    JFC-180BB Chapter 5 System Setting The setup box of [XX TD Right and Left] used in high frequency. It has to be adjusted will be displayed. as it has influence on images. 1. Press 2. Select [TD Setting] - [HF TD Type].
  • Page 82: Setup Of Type Of Low Frequency Transducer

    Chapter 5 System Setting JFC-180BB Type] of low frequency side. 2. Select [TD Setting] - [HF TD1 Setting] 7. Press to close the menu. 3. Press [ ] of The setup box of [HF TD1 Setting] will be Setup of type of low frequency 5.14.2...
  • Page 83: Setup Of Frequency And Beam Angle For Hf 2 Transducer

    JFC-180BB Chapter 5 System Setting 5.14.4 Setup of frequency and beam 5.14.6 Setup of frequency and beam angle for HF 2 transducer angle for LF 2 transducer TD Setting - HF TD2 Setting TD Setting - LF TD2 Setting 1. Press 1.
  • Page 84: Setup Of Bottom Limit Lf

    Chapter 5 System Setting JFC-180BB 4. Pressing [▲] and [▼], select a language 5.14.8 Setup of Bottom Limit LF to be used. TD Setting - Bottom Limit LF 5. Press to close the menu. To set Bottom Limit of low frequency.
  • Page 85: Changing Of Temperature Unit

    JFC-180BB Chapter 5 System Setting 5.15.4 Changing of Temperature Unit Caution: If the Language displayed at the initial power ON is set to Basics - Temperature Unit Japanese, this time difference is The unit of water temperature can be automatically set at 9.0.
  • Page 86: Setup Of Nmea

    Chapter 5 System Setting JFC-180BB The setup box of [GPS Initialize] will be displayed. 4. When initialization is performed, select 4. Select the baud rate at NMEA1 side with [Yes] and initialization is not performed, [▲] and [▼] keys. select [No] with [▲] and [▼] keys.
  • Page 87: Display Of Input Sentence On Nmea Monitor

    JFC-180BB Chapter 5 System Setting 5.16.5 Interval selection of NMEA0183 3. Press [ ] of output Source – NMEA Output Interval The setup box of [XXX Output] will be displayed. The interval of the NMEA0183 output can be selected. 1. Press 2.
  • Page 88: Customization

    Chapter 5 System Setting JFC-180BB 5. Press to close the menu. changed with [▲] and [▼] keys. There are 21 items of which color can be changed. 5.17 Customization 5. Press [ ]. When displayed targets (fish mark, sea bottom, etc.) on the screen are not easy to...
  • Page 89: Changing Of Coloration Of Image Of Color Bar Scale

    JFC-180BB Chapter 5 System Setting 5.17.2 Changing of coloration of image of 5.17.3 Changing of red coloration of Color Bar Scale image of fish display Customize- Color Divide Customize- Fish Disp Col. Adj. The coloration of image of Color Bar Scale When mixed image is displayed, the red will be set.
  • Page 90: Displaying Of Simulation

    Chapter 5 System Setting JFC-180BB 5. Press to close the menu. 5.18.2 Selection of simulation Maintain – Simulation Select This is the function to select a type of simulation image to be displayed. 4. Select [1], [2], or [3] with [▲] and [▼] keys, and [OFF] not to display.
  • Page 91: Returning To The Initialize

    JFC-180BB Chapter 5 System Setting 5.20 Returning to the Initialize The setup screen of [Key Lock* ] will be displayed. Maintain - Initialize This is to return all setup of each CM or the whole system to the factory default settings.
  • Page 92: Confirming Of System Conditions

    Chapter 5 System Setting JFC-180BB The system conditions will be displayed as Caution: When [System ALL] is shown in the above figure. selected, the display will be in English after initialization. When a key is pressed, the key will be 5.21 Confirming of system conditions...
  • Page 93: Updating Of Program

    JFC-180BB Chapter 5 System Setting (5) [Memory] displays the conditions of Load]. internal memory. Ok for normal case and NG for 3. Press [ ] of abnormal case will be displayed. The used ratio of memory is also displayed. The selection box of [System Program Load] will be displayed.
  • Page 94: Storage Of Settings In Flash Memory Device

    Chapter 5 System Setting JFC-180BB [In case of update of the program with the 5. Press [ ] of SD Card or the USB Memory] At completion of downloading, “Normally The setup box of [Save Setting Value] will updated. Turn ON the power again.” will be displayed.
  • Page 95: Setup Of Network

    JFC-180BB Chapter 5 System Setting 4. Using [▲] and [▼] keys, select [SD Card] to network. or [USB Memory] to be applied. When connection to DHCP server is not completed yet, connect using the IP Address set here. 5. Press [ ] of 1.
  • Page 96: Changing Of Subnet Mask

    Network - Input Data Method 2. Select [Network] - [Subnet Mask]. Input method of echo sounder image 3. Press [ ] of information to be received from JFC-180BB can be selected. The setup box of [Subnet Mask] will be 1. Press displayed.
  • Page 97 JFC-180BB Chapter 5 System Setting 1. Press 2. Select [Maintain] - [Image Output]. 3. Press [ ] of The setup box of [Image Output] will be displayed. 4. When the access from PCs is permitted, select [ON] and not permit, [OFF] using [▲] and [▼] keys.
  • Page 98 Chapter 5 System Setting JFC-180BB 5-26 7ZPNA4619A...
  • Page 99: Chapter 6 Ccd Camera

    JFC-180BB Chapter 6 CCD Camera The image on CCD camera will scroll to the Chapter 6 CCD Camera left, right, top and bottom. To display images of CCD camera, prepare a CCD camera separately and connect it Actual image range of CCD camera with a video cable.
  • Page 100: Zoom/Reduce Of Ccd Camera Images

    Chapter 6 CCD Camera JFC-180BB 6.1.3 Zoom/Reduce of CCD camera images This is the function to enlarge a part of CCD camera image for detailed display and to reduce for total view. This is operative under display of CCD camera images on screen.
  • Page 101: Chapter 7 Data Of Sd Card And Usb Memory

    USB memory (with FAT16 or FAT32 format) JRC recommends. When another 7.3 SD Card recommendation type of device is used, JRC JRC recommends the following type and doesn't assure operation. manufacturer of the SD card to be used.
  • Page 102 Chapter 7 Data of SD Card and USB Memory JFC-180BB 7ZPNA4619A...
  • Page 103: Chapter 8 Index

    JFC-180BB INDEX Chapter 8 INDEX A Scope ............... 1-4 Data Reading .........3-7, 4-5, 4-6 Alarm Signal Length ..........2-4 Data Writing ...........3-6, 3-7, 4-5 Alarm1 ........... 2-1, 2-2, 2-3, 2-4 DBT..............5-14 Alarm2 ........... 2-5, 2-6, 2-7, 2-8 Depth Font Size ..........1-10 All IMG DT:DLT ............
  • Page 104 INDEX JFC-180BB GLL ..............5-14 LF TD1 Setting ........... 5-11 GPS Initialize ............. 5-13 LF TD2 Setting ........... 5-11 GPS Select ............5-13 Localtime Offset ..........5-13 Guide Window ............. 5-2 Lower Depth ..........2-1, 2-2 Lower Level ............2-4 Lower Temp Alarm ........
  • Page 105 JFC-180BB INDEX RMC ..............5-14 TX Power (HF) ............. 1-1 TX Power (LF) ............. 1-1 Save Setting Value ..........5-22 Scale ..........1-5, 1-6, 1-7, 5-16 Upper Depth ............2-1 Scale Position ............1-6 Upper Level ............2-3 Scale Value ............1-6 Upper Temp Alarm ..........
  • Page 106 INDEX JFC-180BB 7ZPNA4619A...
  • Page 108 Not use the asbestos For further information,contact: URL Head office : http://www.jrc.co.jp/eng/ Marine Service Department 1-7-32 Tatsumi, Koto-ku, Tokyo 135-0053, Japan            : tmsc@jrc.co.jp e - mail One - call            : +81-50-3786-9201 ISO 9001, ISO 14001 Certified CODE No.7ZPNA4619A DEC. 2018 Edition 3...

Table of Contents