Switch SW06
bit
7
6
5
4
3
2
1
0
on relay, before and after
4-8
Function
Dialling tone
frequency range
Dialling tone
detection time
PSTN dialling tone
detection
Shortcircuit
between digits
in pulse dialling
Shortcircuit time
dialling pulse
set to 1
bit 7 6 = 0 0, 320 / 570 Hz
bit 7 6 = 0 1, 360 / 520 Hz
bit 7 6 = 1 0, 300 / 640 Hz
bit 7 6 = 1 1, 300 / 640 Hz
bit 5 4 3 = 0 0 0, 400 ms
bit 5 4 3 = 0 0 1, 800 ms
bit 5 4 3 = 0 1 0, 900 ms
bit 5 4 3 = 0 1 1, 1200 ms
bit 5 4 3 = 1 0 0, 1800 ms
bit 5 4 3 = 1 0 1, 2000 ms
YES
YES
260 / 70 ms
XEROX DFC165 & DWC165c Service Manual
set to 0
NO
NO
86 / 48 ms