C6220: Fuser edge thermistor high temperature error
1. While drive is stopped, the fuser edge thermistor detected 240°C/464°F or more.
2. During drive, the fuser edge thermistor detected 255°C/491°F or more.
Step
Check description
1
Reinstalling the fuser unit
2
Checking the connection
3
Replacing the fuser unit
4
Checking the connection
5
Replacing the low voltage
PWB.
6
Replacing the main/engine
PWB
C6230: Broken fuser edge thermistor
The fuser thermistor AD value is abnormal.
Step
Check description
1
Reinstalling the fuser unit
2
Checking the connection
3
Replacing the fuser unit
Assumed cause
The fuser unit drawer con-
nector is not inserted com-
pletely.
The connector is not prop-
erly connected or the wire
is faulty.
The fuser edge thermistor
is faulty and cannot detect
correct temperature.
The connector is not prop-
erly connected or the wire
is faulty.
The low voltage PWB is
faulty.
The main/engine PWB is
faulty.
Assumed cause
The fuser unit drawer con-
nector is not inserted com-
pletely.
The connector is not prop-
erly connected or the wire
is faulty.
The fuser edge thermistor
is faulty and cannot detect
correct temperature.
7-84
2RV/2RW/2RX/2RY/3RA-3
Measures
Reinstall the fuser unit so that
the drawer connector is con-
nected securely.
Clean the terminal of the fol-
lowing wire connectors and
reconnect the connectors. If
there is no continuity, replace
the wire.
• Fuser unit - Main/engine
PWB (YC19)
Replace the fuser unit.
Clean the terminal of the fol-
lowing wire connectors and
reconnect the connectors. If
there is no continuity, replace
the wire.
• Low voltage PWB (YC103)
- Main/engine PWB (YC20)
Replace the low voltage
PWB.
Replace the main/engine
PWB.
Measures
Reinstall the fuser unit so that
the drawer connector is con-
nected securely.
Clean the terminal of the fol-
lowing wire connectors and
reconnect the connectors. If
there is no continuity, replace
the wire.
• Fuser unit - Main/engine
PWB (YC19)
Replace the fuser unit.
Reference