Step
Check description
2
(When the paper skew
occurs) Relocating the
paper width guides
3
Replacing the paper
4
Checking the paper
5
Checking the paper
6
Checking the paper
7
Checking the paper
8
Checking the press roller
and fuser belt
J4201/J4202/J4203/J4208/J4209: Exit sensor non-arrival jam
Condition: Paper rolled up on the fuser roller (leading edge margin 4.0mm or more)
When feeding from cassette 1-3, duplex or MP tray, paper is rolled up along the fuser roller and the exit sen-
sor does not turn on.
Step
Check description
1
Checking the press roller
and fuser belt
J4201/J4202/J4203/J4208/J4209: Exit sensor non-arrival jam
Condition: Paper jam after passing the lower exit roller
When feeding from cassette 1-3, duplex or MP tray, paper jams after passing through the lower exit roller and
the exit sensor does not turn on.
Step
Check description
1
(When the paper skew
occurs) Checking the actu-
ator and the spring
2
(In case paper is conveyed
in skew) Checking the
fuser exit guide
Assumed cause
The locations of the paper
width guides do not fit with
the paper size.
The paper curls.
The paper leading edge is
bent.
The paper is wavy.
Unspecified papers are
used.
foreign objects are on the
paper.
Foreign objects adhere to
the press roller or fuser
belt.
Assumed cause
Foreign objects adhere to
the press roller or fuser
belt.
Assumed cause
The actuator does not
operate properly.
The fuser exit guide is
deformed.
7-63
2RV/2RW/2RX/2RY/3RA-3
Measures
Relocate the paper width
guides to fit them with the
paper size.
Replace with long grain
paper.
Remove the bent paper.
Correct or replace paper. If
difficult to replace, re-load
paper by switching top and
bottom ends or turning it over.
Explain to the user to use the
paper within the specifica-
tions.
Remove the paper with for-
eign objects.
Clean the press roller and
fuser belt. Or replace the
fuser unit.
Measures
Clean the press roller or
replace the fuser unit.
Measures
Reattach the exit sensor
actuator and spring. If not
operating properly due to
deformation, correct or
replace them.
Reattach the fuser exit guide.
If the conveying side of the
fuser exit guide is warped,
correct it. If not repaired,
replace the fuser unit.
Reference