3.5 HART communication
3.5.1

Universal commands

The device supports the following universal commands:
Table 3- 3
Command number
0
1
2
3
6
7
8
9
11
12
13
14
15
16
17
18
19
20
21
22
38
48
28
Universal commands
Function
Read Unique Identifier
Read Primary Variable
Read Loop Current And Percent Of Range
Read Dynamic Variables And Loop Current
Write Polling Address
Read Loop Configuration
Read Dynamic Variable Classifications
Read Device Variables With Status
Read Unique Identifier Associated With Tag
Read Message
Read Tag, Descriptor, Date
Read Primary Variable Transducer Information
Read Device Information
Read Final Assembly Number
Write Message
Write Tag, Descriptor, Date
Write Final Assembly Number
Read Long Tag
Read Unique Identifier Associated With Long Tag
Write Long Tag
Reset Configuration Changed Flag
Read Additional Device Status