Connecting
5.4 Transmitter power supply, communications and I/Os connection
See also
Input/output configuration (Page 46)
Inputs (Page 114)
Technical data (Page 113)
5.4.3

Terminal layout

For configuration of the software parameters, see Input/output configuration (Page 46). More
information can be found in the Function Manual.
The following table shows:
● Which cable with which terminal
● Hardware and software configuration of the channels
Figure 5-2
Terminals/configuration overview
Ex and non-Ex versions
● For Ex versions active or passive current output is preselected at ordering and cannot be
changed.
● Non-Ex versions can be connected as either active or passive.
42
SITRANS F Ultrasonic flowmeters FST030 (HART)
Operating Instructions, 08/2017, A5E35971532-AC