Description

SITRANS F US ultrasonic flow meter systems consist of a transmitter and a sensor. The
following table lists the available combinations of transmitters and sensors.

Transmitter

FST030
3.1

Design

3.1.1
Transmitter
The transmitter reads the measured process values from the sensor and calculates derived
values. It provides up to five configurable I/Os, HART communication, USB service channel,
and a local display. It also adds functionalities such as totalizers, access control, diagnostics,
and configuration. The local user interface consists of a display and four buttons for user
interaction.
The transmitter has a modular design with discrete, replaceable electronic modules and
connection boards to maintain separation between functions and facilitate field service. All
modules are fully traceable and their provenance is included in the transmitter setup.
The SITRANS FST030 is available as:
Wall mount enclosure with internal DSL
3.2

Features

● The flowmeter can be used as HART slave in operation on SIEMENS SIMATIC S7/PCS7
or third party automation systems
● Available as wall mount enclosure
SITRANS F Ultrasonic flowmeters FST030 (HART)
Operating Instructions, 08/2017, A5E35971532-AC
Sensor type
FSS200
DN 15 to DN 9000 (0.5" to 360")
3
21