Choosing A Location; Preparing The Site; Power Source Options - Wavion WBS-2400-POE-FCC Installation Manual

Wbs-2400 metro base station
Table of Contents

Advertisement

Installing the Wavion WBS-2400 Metro Base Station

Choosing a Location

The Wavion WBS-2400 is a radio device and susceptible to interference that can reduce
throughput and range. To ensure the best performance follow these guidelines:
Direct line-of-sight operation is preferred.
It is recommend not to install the WBS-2400 near devices operating in the 2.4 GHz
frequency range.
The WBS-2400 should be installed at the highest point of a metal pole such that there will
be no interference caused by RF reflections. If this is not possible, the WBS-2400 should
be installed at least 3 meters from the metal pole.
It is always best to have the maximum distance possible from an RF radiating source.

Preparing the Site

When installing the Wavion WBS-2400, you must follow the appropriate electrical and
building codes to ensure safe and durable wiring. Follow the National Electrical Code (NEC)
requirements, unless local codes in your area take precedence over the NEC code.
For installations that have 10/100 Base-T Category 5 network cables attached to the Wavion
WBS-2400, there is a distance limit of 100m maximum between devices for 10/100BaseT
operation.
An appropriate ground cable should be available. Grounding through electrical wiring or CAT-
5 cable is not sufficient.
Please refer to standards for building entrance protection.

Power Source Options

The Wavion WBS-2400 supports the following options for connecting to a power source:
AC power source (3-wire service) — 3W(P+N+PE) or 3W(2P+PE); 110-220 VAC, 50/60
Hz. See
Chapter 7: Installation Accessories
NEMA plug, for streetlight photoelectric control power tap (2-wire service) —2W(2P) or
2W(P+N); 100-240 VAC 50/60 Hz. See
details.
DC power source (2-wire service); 48VDC See
page
55
for details.
The WBS-2400 can be powered by a Wavion Injector connected to Ethernet port B (ETH
B). See
Chapter 7: Installation Accessories
W
ARNING
system. Do not connect to a power source of different voltage.
12 Wavion
:
Use only a rated power source to connect the AC powered outdoor
on page
55
for details.
Chapter 7: Installation Accessories
Chapter 7: Installation Accessories
on page
55
for details.
on page
55
for
on

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents