Grounding The Data Protection Device - Wavion WBS-2400-POE-FCC Installation Manual

Wbs-2400 metro base station
Table of Contents

Advertisement

Attach #10 AWG bare copper wire with an M6 terminal ring to the grounding screw.
3.
Attach wire to
grounding
screw
Attach the second star washer and tighten the nut.
4.
Attach the other end of the grounding wire to a grounding strap that is attached to a
5.
grounded surface or other earth ground (for example, a grounding rod).

Grounding the Data Protection Device

The grounding method for an indoor data protection device is shown in
To ground an indoor data pr otection device
Position the protection device as close to the entrance of the building entrance as possible.
1.
Attach a length of #10 AWG bare copper wire to the ground post on the data protection
2.
device.
Attach the other end of the grounding wire to the ground connection of an electrical outlet
3.
or a grounded water pipe.
Installing the Wavion WBS-2400 Metro Base Station
Figure
3.17.
Installation Guide
25