Installing the Wavion WBS-2400 Metro Base Station
Reenergize the circuit and confirm that the power to the WBS-2400 comes on.
7.
N
:
OTE
fuse branch circuit protection. AC current protection of 20Amp should be installed.
N
:
OTE
closure cap when not in use and tighten the cap. See
Accessories

Connecting to DC Power

The DC power connections for a DC power source are shown in
W
ARNING
connections must conform to local uniform building codes.
Figure 3.22. Connecting DC Power
D C Power source
To c onnect an DC power source
Verify that the service voltage is the following: 48VDC in the correct polarity.
1.
Connect positive Voltage to White wire of the DC cable.
2.
Connect Negative Voltage to Black wire of the DC cable.
3.
Make sure the power is turned off on the designated circuits.
4.
Install a 1/2 inch liquid-tight conduit from the building entrance point to within 3 feet of
5.
the outdoor system.
32 Wavion
The Wavion WBS-2400 is equipped with additional AC surge protection and
Do not leave connectors open to the environment. Cover connectors with the
on page 55.
:
All wiring should be performed by a licensed electrician. All wiring and
Black (-)
W hite (+)
Chapter 7: Installation
M ain C ircuit Braker
Figure
3.22.