Poe Power Sourcing Power Output; Using A Backhaul Unit - Wavion WBS-2400-POE-FCC Installation Manual

Wbs-2400 metro base station
Table of Contents

Advertisement

PoE Power Sourcing Power Output

Voltage
48VDC
24VDC
12VDC
W
ARNING
ports (ETH A or ETH B) is sourcing power to the external device. If both ports are
powering the external device the total output power should not exceed 30W.
N
:
The output power support is available on selected models. Please refer to
OTE
appendix A: WBS-2400 Product list.
N
:
PoE output can only be supported if the WBS-2400 is powered by AC or DC
OTE
voltage input.
N
:
Use only shielded Cat5e cable rated for outdoor use.
OTE
Accessories
hazard and to ensure the reliable operation of this equipment, the shields of the Cat5
cable must be properly terminated and bonded to the unit and to the protective earth
(PE) at the building entrance.
ETH A and ETH B RJ45 Pin Descriptions for Data Connection
Pin
T/R
1
T
2
R
3
T
4
R
5
T
6
R
7
T
8
R

Using a Backhaul Unit

If the installation location does not provide a place to connect to the internet (for example,
on an electricity pole), you need to use a backhaul unit.
There are two types of backhaul units:
A backhaul unit that provides its own power
Max Power Output
30W
24W
12W
:
Table above defines maximum output power in case that only one of two
on page
55
for details. For protection against risk of fire, electrical
Signal
Color
TXD+
Orange-White
TXD-
Orange
RXD+
Green-White
PoE+
Blue
PoE+
Blue-White
RXD-
Green
PoE-
Brown-White
PoE-
Brown
Installing the Wavion WBS-2400 Metro Base Station
Description
TX Data 10/100BaseT
TX Data 10/100BaseT
RX Data 10/100BaseT
Power output, 12/24/48 VDC (+)
Power output, 12/24/48 VDC (+)
RX Data 10/100BaseT
Power output, 12/24/48 VDC (-)
Power output, 12/24/48 VDC (-)
Chapter 7: Installation