Installing the Wavion WBS-2400 Metro Base Station

Connecting a Data Port

The Wavion WBS-2400 is equipped with four RJ45 connectors. The left hand port named
"SERIAL" is for engineering use only. Use the ETH A port if you are connected to the external
unit (backhaul, camera, and etc.) for which you have to supply 12/24VDC power. Use the
ETH B port if you are connected to external unit for which you have to supply 48VDC power.
In case you do not need to power an external device you can connect either ETH A, ETH B, or
ETH C ports. All three Ethernet ports can be active simultaneously.
N
:
OTE
Installation Accessories
must be properly terminated and bonded to the unit and to the protective earth (PE)
at the building entrance. This provides protection against the risk of fire, electrical
hazard and ensures the reliable operation of this equipment,
N
:
OTE
Listed (UL/CSA) Building Entrance Protector for all power and communications cables
entering a building. Article 800 is intended to protect the building and occupants
from fires caused by transient voltage and current surges.
W
ARNING
7,8 (-)
N
:
OTE
Over Ethernet devices.
34 Wavion
Use only shielded Cat5e cable rated for outdoor use.
on page
National Electrical Codes (NEC) Article 800 requires the use of an Agency
:
DC voltage may be present on Ethernet A and Ethernet B pins 4,5 (+) and
This is not a mid-span powered device. Do not attempt to daisy-chain Power
for details.
55
The shields of the Cat5 cable
See
Chapter 7: