Vega VEGABAR 52 Operating Instructions Manual page 59

4...20 ma/hart
Hide thumbs Also See for VEGABAR 52:
Table of Contents

Advertisement

For one year
-
For five years
-
For ten years
-
Ambient conditions
Ambient, storage and transport temperature
Standard version
-
Versions IP 66/IP 68 (1 bar) and IP 68
-
(25 bar), connection cable PUR
Version IP 66/IP 68 (1 bar), connection
-
cable PE
Process conditions
The specifications of the pressure stage and product temperature are used as an overview. The
specifications on the type label are applicable.
Pressure stage, process fitting
Thread 316L
-
Thread Aluminium
-
Thread PVDF
-
Hygienic fittings 316L
-
Flange 316L
-
Flange with extension 316L
-
Flange flattened on both sides 316L
-
Flange PVDF
-
Product temperature depending on the measuring cell seal
Measuring cell seal
FKM (VP2/A)
FKM (A+P 70.16)
EPDM (A+P 75.5/KW75F)
EPDM (ET 7056)
VEGABAR 52 • 4 ... 20 mA/HART
Product temperature -
standard version
-20 ... +120 °C
(-4 ... +248 °F)
-40 ... +120 °C
(-40 ... +248 °F)
-40 ... +120 °C
(-40 ... +248 °F)
1 h: 140 °C/284 °F clea-
ning temperature
-40 ... +120 °C
(-40 ... +248 °F)
1 h: 140 °C/284 °F clea-
ning temperature
With process fitting PVDF, max. 100 °C (212 °F).
13)
< 0.05 % x TD
< 0.1 % x TD
< 0.2 % x TD
-40 ... +80 °C (-40 ... +176 °F)
-20 ... +80 °C (-4 ... +176 °F)
-20 ... +60 °C (-4 ... +140 °F)
PN 60
PN 25
PN 10
PN 6, PN 10, PN 25, PN 40
PN 16, PN 40,150 lbs, 300 lbs, 600 lbs
without PN specification, PN 16, PN 40 or 150 lbs,
300 lbs, 600 lbs
PN 10
PN 16
13)
Product temperature - version with extended
temperature range
-20 ... +150 °C (-4 ... +302 °F)
-
-40 ... +150 °C (-40 ... +302 °F)
-
10 Supplement