Measuring Flow Rate Of Hot Beverage - Krups KP 5000 Service Manual

Dolce gusto
Table of Contents

Advertisement

F U N C T I O N   T E S T S 
Measuring flow rate of hot beverage 
1.  Switch machine ON. 
2.  Place a measuring beaker under 
outlet. 
3.  Insert an espresso capsule in 
capsule holder. 
7.  Wait until 40 ml coffee has flown in 
the measuring beaker. 
8.  Stop timer. 
The measured time must be within 
9 ­ 15 sec.
4.  Insert capsule holder and push it 
down. 
5.  Set selection lever at position 
(hot). 
6.  Start timer simultaneously. 