Check
procedure
3.1 Water tank is leaking on
transport
3 Fill water tank
3.2 Water tank is leaking when it
is inserted in the machine
4 Plug into mains
4.1 Machine (with capsule
and switch ON
holder inserted) is not working
machine
no function
T R O U B L E S H O O T I N G
Symptoms
Action / repair work
YES Replace water tank
NO Go to point 3.2
YES a) Check if snap connection
for water tank on housing back is
functional
YES b) Try new water tank and
check if it is still leaking
NO Go to point 4
YES a) Check if magnets of
capsule holder are in place.
YES b) Check if power cord is
functional
YES c) Check if all electrical
connectors are connected
YES d) Check if thermoblock's
thermofuses (133°C) are defective
YES e) Check if power button is
functional
YES f) Check if indicator (LED) is
defective
YES g) Check if reed contact is
functional
YES h) Check if pump is working
(
at position
(cold)
YES i) Check if pump is working at
)
position
(hot)
YES j) Check if pump's thermal
cut off fuse (98°C) is defective
Further action /
repair work
—
YES Go to point b)
NO Replace housing back
YES Replace connector (tank
to pump), filter and water tank
NO Replace old water tank
YES Go to point b)
NO Replace capsule holder
YES Go to point c)
NO Replace it.
YES Go to point d)
NO Connect them
YES Replace power cord and
PCB assembly. If necessary
replace also the thermoblock
NO Go to point e)
YES Go to point f)
NO Check if PCB support and
housing left are assembled
correctly. Replace PCB
assembly or housing left if
necessary.
YES Replace PCB assembly
NO Go to point g)
YES Go to point h)
NO Replace extraction head
YES Go to point i)
NO Go to point j)
YES Go to point 4.3
NO Replace the extraction
head (valve switch might be
broken). If still
not working, replace also PCB
assembly.
YES Replace pump.
NO Replace pump
or PCB assembly
or extraction head