Krups KP 5000 Service Manual page 49

Dolce gusto
Table of Contents

Advertisement

Use a pair of pliers to 
fix the spring.
Wrong NTC wire
routing can cause
malfunctions.
R E P A I R 
7.  Apply a sufficient amount of standard heat conducting paste into socket (b). 
8.  Attach a new clamp spring (c) on the new NTC temperature sensor (a). 
9.  Tilt clamp spring on sensor body. 
10.  Insert NTC temperature sensor (a) in socket (b) partly so that both spring ends are 
in the socket already. 
11.  Place a piercer (or the blade of a screwdriver) on opposite clamp shoulder. 
12.  Drive clamp spring down the socket with light blows of a hammer. 
Assembly information 
• 
Check that the new NTC temperature sensor is pressed down at the bottom of the 
socket. 
• 
Route NTC wires according to machine version. 
• 
Plug in NTC connector in main PCB. 

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kp 5002Kp 5006Kp 5005

Table of Contents