Use a pair of pliers to 
fix the spring.
Wrong NTC wire
routing can cause
malfunctions.
R E P A I R 
7.  Apply a sufficient amount of standard heat conducting paste into socket (b). 
8.  Attach a new clamp spring (c) on the new NTC temperature sensor (a). 
9.  Tilt clamp spring on sensor body. 
10.  Insert NTC temperature sensor (a) in socket (b) partly so that both spring ends are 
in the socket already. 
11.  Place a piercer (or the blade of a screwdriver) on opposite clamp shoulder. 
12.  Drive clamp spring down the socket with light blows of a hammer. 
Assembly information 
• 
Check that the new NTC temperature sensor is pressed down at the bottom of the 
socket. 
• 
Route NTC wires according to machine version. 
• 
Plug in NTC connector in main PCB. 