Check
procedure
5.3 Hot water temperature is too
high (more than 95°C / 203 °F)
5 Checks while
preparing a beverage
5.4 Cold water temperature too
high (5°C / 41°F more than water
tank temperature)
5.5 Selection lever does not
remain at the position
or
5.6 The capsule does not fall out
of the capsule holder
6.1 Leakage at extraction head
6.2 Water underneath the
machine
6.3 Leakage at pressure hoses
6 Check for leaks
connections
and/or flow rate
while preparing a
beverage.
6.4 Flow rate out of range
T R O U B L E S H O O T I N G
Symptoms
(
(cold)
)
( hot)
Action / repair work
YES a) Check if NTC temperature
sensor is functional
YES b) Fluid system is scaled?
YES d) Flow rate of pump out of
range?
YES Valve malfunction?
NO Go to point 5.5
YES Replace the extraction head
NO Go to point 5.6
YES Check the capsule or the
capsule holder
NO Go to point 6
YES a) The capsule has multiple
perforations?
NO Go to point 6.2
YES Defective pressure hoses
and/or silicone elbow?
NO Go to point 6.3
YES Defective pressure hoses
and clips?
NO Go to point 6.4
YES a) Fluid system is scaled?
YES b) Injector plate is blocked?
YES c) Filter is blocked?
Further action /
repair work
NO Change NTC tempera
ture sensor.
YES Go to point b)
YES Descale the fluid system
NO Go to point 5.5
YES Replace the pump.
NO Go to point 5.4
YES Replace the extraction
head.
NO Go to point 5.6
YES Replace the capsule
holder if necessary
YES Perforate the capsule
only once, see user manual
NO Replace the extraction
head.
YES Replace defective pres
sure hoses, clips and/or sili
cone elbow
NO Go to point 6.4
YES Replace defective pres
sure hoses and clips
NO Go to point 6.4
YES Descale the fluid system
NO Go to point b)
YES Deblock injector of
injector plate
and descale again.
NO Go to point c)
YES Replace filter.
NO Replace pump.