Empty Fluid System For Shipping - Krups KP 5000 Service Manual

Dolce gusto
Table of Contents

Advertisement

For shipping a
machine, it is
important to empty the
fluid system.
The machine will
not work without
inserted capsule holder.
Prolonged dry-
running can dam-
age the pump.
O P E R A T I N G 
Empty fluid system for shipping
1.  Empty water tank and drip tray. 
4.  Set selection lever at position 
(cold water). Let water run through 
for approx. 5sec. 
6.  Set selection lever at middle position. 
7.  Remove and empty jug. 
2.  Check that capsule holder is empty. 
3.  Re­insert capsule holder. 
5.  Set selection lever at position 
(hot water). Let water run through 
for approx. 5 sec. 
12. Clean machine and all  accessories. 
13. Send machine back with capsule 
holder and all provided accessories.

Hide quick links: