Download  Print this page

Krups KP 5000 Service Manual Page 18

Dolce gusto.
Hide thumbs

Advertisement

Table of Contents
Check 
procedure 
4.2 Indicator (LED) flashes red 
3 times a second (error mode) 
4 Plug into mains 
and switch ON 
4.3 Machine is working without 
machine 
capsule holder 
4.4 Machine is hissing if valve 
handle is in middle position 
4.5 No cup lighting 
5.1 No extraction possible (no 
water at coffee outlet) 
5 Checks while 
preparing a beverage 
5.2 Hot water temperature is too 
low (less than 70°C / 158 °F) 
Symptoms 
YES ­ a) Check if NTC temperature 
sensor is functional 
YES ­ b) Check if electrical wires 
are functional 
NO ­ Go to point 4.3 
YES ­ Replace the extraction head 
NO ­ Go to point 4.4 
YES ­ Replace the extraction head 
NO ­ Go to point 5 
YES ­ Check if cable connector and 
cup lighting wiring are functional 
NO ­ Go to point 5 
YES ­ a) Water tank is empty? 
YES ­ b) Water tank is correctly 
inserted? 
YES ­ c)  Filter is blocked or not in 
right position 
YES ­ d) Fluid system is empty? 
YES ­ e) Fluid system is blocked by 
scale? 
YES ­ f) Injector is still clogged after 
descaling? 
YES ­ a) Check if NTC temperature 
sensor is functional 
YES ­ b) Fluid system is scaled? 
YES ­ c) Valve malfunction? 
YES ­ d) Flow rate of pump out of 
range? 
T R O U B L E S H O O T I N G 
Action / repair work 
Further action / 
repair work
NO ­ Replace NTC tempera­ 
ture sensor.
YES ­ Go to point b) 
YES ­ Replace PCB assembly 
NO ­ Replace defective(s) 
wire(s).
YES ­ Replace cup lighting or 
PCB assembly.
NO ­ Fix lose connection(s) 
YES ­ Fill water tank 
NO ­ Go to point b) 
YES ­ Go to point c) 
NO ­ Insert water tank 
correctly 
YES ­ Replace filter.
NO ­ Go to point d) 
YES ­ Prime the fluid system 
without capsule.
NO ­ Go to point e) 
YES ­ Descale the fluid system 
NO ­ Go to point f) 
YES ­ Deblock the injector 
NO ­ Replace the extraction 
head.
NO ­ Change NTC tempera­ 
ture sensor.
YES ­ Go to point b) 
YES ­ Descale the fluid system 
NO ­ Replace PCB assembly 
YES ­ Replace the extraction 
head.
NO ­ Go to point d) 
YES ­ Replace the pump.
NO ­ Go to point 5.3 

Advertisement

Table of Contents

This manual is also suitable for:

Kp 5002Kp 5006Kp 5005

Comments to this Manuals

Symbols: 0
Latest comments: