The PCB of the
power button is part
of the PCB assembly
and cannot be replaced
separatedly.
R E P A I R
Replacing PCB assembly
The PCB assembly consists of
a main PCB (O)
and a small PCB (P) for the power button.
1. Remove housing left first.
2. Unplug 3 connectors from main PCB:
Valve Detection (to microswitch in extraction head)
Capsule Holder (to reed contact in extraction head)
NTC (to thermoblock)
3. Unplug pigtail of main pcb from cup lighting assembly.
4. Unplug 4 flat receptacles from main pcb:
Pump
Line
Neutral
Heater