General Information; Introduction; Description; Power Supply - Advantech SSPBMg–C200–BRE Installation And Operating Manual

Solid state power block up-converter
Table of Contents

Advertisement

SSPBMg-C200-BRE

2. GENERAL INFORMATION

2.1 INTRODUCTION

This manual contains information that describes the installation, operation and maintenance
procedures for the 200-Watt C-Band hub-mount (outdoor) Solid State Power Block Up-
Converter model SSPBMg-C200-BRE. Because specialized training is required for some phases
of installation and operation, certain parts of this manual are directed only to properly trained
personnel. Warnings appear at the appropriate points to caution all users of the potential RF
hazards.
For a safe and versatile operation, please read the information carefully BEFORE using the
equipment.
Advantech Wireless has prepared this manual for use as a guide for the proper installation,
operation and maintenance of Advantech Wireless equipment and computer programs. The
drawings, specifications and information contained herein are the property of Advantech
Wireless. Unauthorized use or disclosure of these drawings, specifications and information is
strictly prohibited. They shall not be reproduced, copied or used in whole or in part as the basis
for manufacturing or sale of the equipment or software programs without the prior written
consent of Advantech Wireless.

2.2 DESCRIPTION

The SSPBMg-C200-BRE is a 200-Watt C-Band hub-mount (outdoors) Solid State Power Block
Up-Converter (SSPB). The entire SSPB is self-contained and is intended for mounting on to the
antenna hub, see Figure 1: Product Outline at page 11. It incorporates an Interface Assembly, Up-
Converter Assembly, High Power Amplifier (HPA) Assembly, Power Supply Assembly and a Main
Controller Board. The block diagram of the SSPB is shown in Figure 2: Block Diagram (page 12)
and the various connectors are shown in Figure 3: Connectors (page 15).
2.2.1 P
S
OWER
UPPLY
There are two power supply assemblies in this SSPB. The first power supply provides +12 V DC
high current and – 9 V DC low current for the SSPB and +12 V DC for the fans. The second
power supply provides +48 V DC for the final GaN devices in the High Power Amlifier
Assembly. The unit is configured for operation from 90 - 264 V AC, single phase, 47-63 Hz.
It has a Power Factor Correction (PFC) of 95%, minimum.
The overall power consumption is 750 W (@ P
RF Output Power) and 900 W (@ P
RF
LIN
SAT
Output Power), typical.