Command Message Structure (Idu To Sspb); Value; Table 15: Command Message Structure - Advantech SSPBMg–C200–BRE Installation And Operating Manual

Solid state power block up-converter
Table of Contents

Advertisement

12.3.2 C
M
OMMAND
ESSAGE

TABLE 15: COMMAND MESSAGE STRUCTURE

Byte
Name
1
Address
2
Command Request Status
3
Data Byte 1 Not used if command = 0x01
4
Data Byte 2 Not used if command = 0x01
5
Data Byte 3 Not used
6
Data Byte 4 Not used
7
Checksum
S
(IDU
TRUCTURE
Description
Address of SSPB
Transmit ON/OFF
Change Address
Set Input Frequency
Not applicable for these units
Tx control if command = 0x02
New address if command = 0x03
Input Frequency if command = 0x04
Not applicable for these units
Not used if command = 0x02
Not used if command = 0x03
Input Frequency if command = 0x04
Not applicable for these units
Algebraic sum of bytes 1 – 6, modulo
256
SSPB)
TO
0x01 to 0x0F
0x01
0x02
0x03
0x04
Not applicable for these units
0xAA
0 = OFF, 1 = ON
0x01 to 0x0F
MS byte (most significant byte)
Not applicable for these units
0xAA
0xAA
0xAA
LS byte (least significant byte)
Not applicable for these units
0xAA
0xAA
SSPBMg-C200-BRE