6.3.
Time clock regeneration (604 only)
Set the time between each regeneration.
A
Press
until desired interval appears then release.
→ Range from 0 through 30;
0 = Disabled;
0.3 = Regeneration every 8 hours : at 2, 10 and 18 hours;
0.5 = Regeneration every 12 hours : at 2 and 14 hours;
1 - 30 = Regeneration every X days (every 3 days in this
example).
6.4.
Volumetric regeneration (606 only)
3
Set the capacity in [m
A
Press
until desired capacity appears then release.
→ Range from 0.4 to 9.5 m
3
from 0.4 m
to 1.0 m
(12 increments);
3
from 1.0 m
to 3.0 m
3
from 3.0 m
to 5.0 m
3
from 5.0 m
to 9.5 m
6.5.
Calendar override setting (606 only)
The 606 controller needs a method to set days between regeneration for regulatory requirements and
in cases when the flow sensor has failed.
A
Press and hold
→ The programmed calendar override is displayed.
B
Press
to increases value.
→ Range from 0 through 30;
0 = Disabled;
0.3 = Regeneration every 8 hours : at 2, 10 and 18 hours;
0.5 = Regeneration every 12 hours : at 2 and 14 hours;
1 - 30 = Regeneration every X days (every 3 days in this
example).
Ref. MKT-IM-007 / A - 16.12.2016
] between each regeneration.
3
;
3
by increments of 0.05 m
3
by increments of 0.1 m
3
by increments of 0.2 m
3
by increments of 0.5 m
and
for 3 seconds.
Installer Manual Autotrol 368 / 604-606 - Programming
3
3
(20 increments);
3
(10 increments);
3
(10 increments).
29 / 54