5.6.
Connections (electrical)
AC adapter cable connection
Motor and optical sensor cable connection
Meter cable connection (368 / 606 only)
5.7.
Drain line flow controller
The DLFC requires assembly before use.
A
Note
The plumbing connectors should not be installed. See 5.8.1. Bypass assembly, page 24.
A
Using a PTFE (plumber's tape), wrap it over threads of the flow controller (2).
B
Screw the flow controller (2) and the 90° elbow (1) together (hand tighten).
C
Place the ball (5) into the flow controller (2) and insert the assembly into the drain line opening
(4).
D
Push the assembly in and secure with the drain line clip (3).
Ref. MKT-IM-007 / A - 16.12.2016
Installer Manual Autotrol 368 / 604-606 - Installation
AC adapter connection
23 / 54