Maintenance; Recommendations; Use Original Spare Parts; Use Original Approved Lubricants - Pentair AUTOTROL 604 Installer Manual

Fully integrated valve/control combination
Hide thumbs Also See for AUTOTROL 604:
Table of Contents

Advertisement

9.

Maintenance

A
Mandatory
Cleaning and maintenance shall take place at regular intervals in order to guarantee the
proper functioning of the complete system, and be documented in the Maintenance chapter
in the User Guide document.
9.1.

Recommendations

9.1.1. Use original spare parts

A
Caution
To ensure correct operation and safety of the device, only use original spare parts and
accessories recommended by the manufacturer.
Parts to keep in stock for potential replacements are motor and optical sensor, controller,
transformer, injectors, flapper kit, O-ring kit, refill flow controller and DLFC.

9.1.2. Use original approved lubricants

Production:
p/n 1014082 (NFO "Chemplex" 862 Silicone Comp.).
Spare part:
p/n 42561 (SILICONE LUBRICANT PACK).

9.1.3. Maintenance instructions

Disinfect and clean the system at least once a year or if the treated water has an off-taste or an
unusual odour.
Perform a hardness test every year for softeners.
9.2.

Cleaning and maintenance

9.2.1. Cleaning and maintenance
Before any cleaning or maintenance procedure, complete the following step :
No.
A
Caution
These operations need to be performed before any cleaning or maintenance procedure.
A
Unplug the wall-mounted transformer.
B
Shut off water supply or put bypass valve(s) into bypass position.
C
Relieve system pressure before performing any operations.
Ref. MKT-IM-007 / A - 16.12.2016
Installer Manual Autotrol 368 / 604-606 - Maintenance
Operation
37 / 54

Hide quick links: