Installer Manual Autotrol 368 / 604-606 - Programming
6.6.

System selection

The 604 / 606 controller has four system settings available. The system selections accommodate
multiple tank sizes and various feedwater conditions.
System selection:
A
Press and hold
→ A small "u" will be displayed in the left digit.
→ The right digit will display the current system setting.
B
Press
until desired system setting appears then release.
→ The displayed system setting will be stored in flash memory
when the controller exits programming after 5 seconds.

6.6.1. Programmed settings

C#
Cycle
C1
Backwash
Brine draw
C2
Slow rinse
C3
Repressurize
C4
Fast rinse
C5
2nd backwash
C6
2nd fast rinse
C7
Brine refill
6.7.

Resetting the controller

All programmed settings with the exception of time of day can be reset. Entering the value "0" will
reset the flash memory to the factory default.
To reset the controller:
A
Press and hold
→ A small "u" will be displayed in the left digit.
→ The right digit will display the current system setting.
B
Press
until the "u0" system is displayed.
→ Wait 5 seconds for the setting to be stored into the flash
memory. The display will return to the time of day.
→ The controller has now system 1 setting (default setting).
C
Follow the steps of the system selection procedure to select
the desired system setting.
30 / 54
and
simultaneously for 3 seconds.
Resin bed
flow
direction
Calculated
None
None
Calculated
and
simultaneously for 3 seconds.
System u# [minutes]
u1
u2
8
8
Calculated
25
45
3
3
3
3
1
1
1
1
Calculated
Ref. MKT-IM-007 / A - 16.12.2016
u3
u4
1
3
Calculated
Calculated
25
45
3
3
1
31
1
1
1
1
Calculated
Calculated