2 Mechanical Installation

2
Mechanical Installation
Upon Receipt
Please perform the following tasks after receiving the drive:
• Inspect the drive for damage. If the drive appears damaged upon receipt, contact your
supplier.
• Verify receipt of the correct model by checking the information on the nameplate. If you
have received the wrong model contact your supplier.
Installation Environment
For optimum performance life of the drive, install the drive in an environment that meets the
conditions listed below.
Environment
Installation Area
Ambient Temperature
Humidity
Storage Temperature
Surrounding Area
Altitude
Vibration
Orientation
EN 10
Indoors
IP20/NEMA Type1 enclosure: -10 to +40C
IP20/IP00 Open-Chassis enclosure: -10 to +50C
Finless Type: IP20 enclosure: -10 to +50C
When using an enclosure panel, install a cooling fan or air conditioner in the area to
ensure that the air temperature inside the enclosure does not exceed the specified levels.
Do not allow ice to develop on the drive.
95% RH or less and free of condensation
-20
C to +60
C
Install the drive in an area free from:
• oil mist and dust
• metal shavings, oil, water or other foreign materials
• radioactive materials
• combustible materials (e.g., wood)
• harmful gases and liquids
• excessive vibration
• chlorides
• direct sunlight
1000 m or less
10 Hz to 20 Hz at 9.8 m/s
Install the drive vertically to maintain maximum cooling effects.
YASKAWA ELECTRIC TOEP C710606 27C - AC Drive J1000 - Quick Start Guide
Conditions
, 20 Hz to 55 Hz at 5.9 m/s
2