YASKAWA J1000 CIMR-JC series Quick Start Manual page 25

Compact v/f control drive
Hide thumbs Also See for J1000 CIMR-JC series:

Advertisement

Par.
Name
1:2.0 kHz
2:5.0 kHz
3:8.0 kHz
Carrier
4:10.0 kHz
C6-02
Frequency
5:12.5 kHz
Selection
6:15.0 kHz
7:Swing PWM
F: User defined
Frequency References
d1-01
Frequency
Set the multi-speed references 1 to
to
Reference
8.
d1-08
1 to 8
d1-17 Jog Speed
Jog speed
V/f Pattern
Input
E1-01
Voltage
Input Voltage
Setting
Max.
E1-04
Output
For a linear V/f characteristics, set
Frequency
the same values for E1-07 and
E1-09. In this case, the setting for
Max.
E1-08 will be disregarded.
E1-05
Output
Ensure that the four frequencies
Voltage
are set according to these rules or
Base
an oPE10 fault will occur:
E1-06
Frequency
E1-04  E1-06 > E1-07  E1-09
Mid.
E1-07
Output
Frequency
(E1-05)
Mid.
E1-08
Output
Voltage
(E1-08)
Min.
E1-09
Output
Frequency
(E1-10)
Min.
E1-10
Output
Voltage
Motor Data
Motor
E2-01
Rated
Motor rated current in Ampere.
Current
Motor
E2-02
Motor rated slip in hertz (Hz).
Rated Slip
YASKAWA ELECTRIC TOEP C710606 27C - AC Drive J1000 - Quick Start Guide
Description
Output voltage
(E1-09)
(E1-07)
(E1-06)
Output frequency
Par.
Name
Motor
E2-03
No-Load
Current
Motor
E2-05
Line-to-Line
Resistance
DI
H1-01
S1 to S5
to
Function
H1-05
Selection
A list of the major functions can be found at the table end.
DO
H2-01
MA/MB
Function
Major functions are listed at the end of the table.
A1 Signal
H3-01
Level Sel.
H3-03 A1 Gain
H3-04 A1 Bias
AM
H4-01
Monitor
Selection
H4-02 AM Gain
H4-03 AM Bias
(E1-04)
Motor
L1-01
Overload
Prot. Sel.
Motor
L1-02
Overload
Prot. Time
6 Parameter Table
Description
Magnetizing current in Ampere.
Sets the phase-to-phase motor
resistance in ohms.
Digital Input Settings
Selects the function of terminals
S1 to S5.
Digital Output Settings
Set the function for the relay
output MA-MB-MC.
Analog Input Setting
0:0 to +10 V (neg. input is zeroed)
1:0 to +10 V (bipolar input)
2:4 to 20 mA (9 bit input)
3:0 to 20 mA
Sets the input value in % at 10 V/
20 mA analog input.
Sets the input value in % at 0 V/0
mA/4 mA analog input.
Analog Input Setting
Enter value equal to U1-
monitor values. Example: Enter
"103" for U1-03.
Sets terminal AM output voltage
equal to 100% monitor value.
Sets terminal AM output voltage
equal to 0% monitor value.
Motor Overheat Protection
Sets the motor overload
protection.
0:Disabled
1:Standard fan cooled motor
2:Standard blower cooled motor
Sets the motor overload protection
time in min. Normally no change
is necessary.
EN 25