Phase Angle
Phase Range:
100V TR-Range
0.8 ... 240
241 ... 2000
2001 ... 4000
4001 ... 13000
13000 ... 16000 ±0.50°
40V
TR-Range
0.8 ... 240
241 ... 2000
2001 ... 4000
4001 ... 13000
13000 ... 16000 ±0.55°
10V
TR-Range
0.8 ... 60
61 ... 500
501 ... 3250
3251 ... 4000
1V
TR-Range
0.8 ... 6
7 ... 50
51 ... 325
326 ... 400
Specifications
Model TR-MARK III
•
Size L: 470 mm (18.5") W: 371 mm (14.6") H: 190 mm (7.5")
•
Weight 9.5 kg (21 lbs.)
•
Input Power 100 to 250 VAC 50/60 Hz auto ranging. Fuse: 2A
•
Test Voltage User Selectable: 100, 40, 10, and 1VAC.1A
•
Panel Display Color LCD with back lighting and touch screen
•
Front Panel Sealed, Anodized
•
Interface 2 USB 1.1 (1 host/1 device) and 9 Pin RS232 serial
•
Memory Storage Internally stores more than 10 000 test results
•
Temperature Operating –10° C to 60 ° C, Storage –20°C to 70° C
•
Accessoires
Acc. Complete cable set (consisting of a 5 m cable with an extension cable of 10 m),
•
cable carrying bag, instruction manual, software for data download
•
Options
TRO203 External test switch for Tap changer testing
•
T-REX 3-phase Supply to energize all 3 phases at once
•
TR-MARK IIIR 19", 4U Rackmount version
•
* Specifications are subject to improvement at anytime
90100.1.02 Instruction Manual TR-MARK III
±90 Degree, Resolution: 0.01°
Accuracy
±0.05°
Rdg ±1 LSD
±0.10°
Rdg ±1 LSD
±0.15°
Rdg ±1 LSD
±0.40°
Rdg ±1 LSD
Rdg ±1 LSD
Accuracy
±0.10°
Rdg ±1 LSD
±0.15°
Rdg ±1 LSD
±0.20°
Rdg ±1 LSD
±0.45°
Rdg ±1 LSD
Rdg ±1 LSD
Accuracy
±0.15°
Rdg ±1 LSD
±0.25°
Rdg ±1 LSD
±0.55°
Rdg ±1 LSD
±0.65°
Rdg ±1 LSD
Accuracy
±0.15°
Rdg ±1 LSD
±0.25°
Rdg ±1 LSD
±0.55°
Rdg ±1 LSD
±0.65°
Rdg ±1 LSD
Page 47 of 70
Need help?
Do you have a question about the TR-MARK III and is the answer not in the manual?
Questions and answers