Incipient Fault Detector; Remaining Connection Status; Parallel Redundancy Protocol (Prp) - GE L30 Instruction Manual

Line current differential system
Hide thumbs Also See for L30:
Table of Contents

Advertisement

STATUS

6.3.17 Incipient fault detector

ACTUAL VALUES  STATUS  INCIPIENT FAULT  INCIPIENT FAULT 1
 INCIPIENT FAULT 1
The number of detected incipient faults for each incipient fault element are displayed here for each phase. These values
can be reset to zero with the

6.3.18 Remaining connection status

ACTUAL VALUES  STATUS  COMM STATUS REMAINING CONNECT
 COMM STATUS
 REMAINING CONNECT
6
These values specify the remaining number of TCP connections still available for each protocol. The display depends on the
options applicable to your device. Each time a connection is used, the remaining number of connections decrements.
When released, the remaining number of connections increments. If no connection is made over the specific protocol, the
number equals the maximum number available for the specific protocol.
For example, the maximum number of Modbus TCP connections is 4. Once an EnerVista session is opened on a computer
connected to the UR over Ethernet, the Modbus TCP status shows 3. If the EnerVista application is closed, the Modbus TCP
status shows 4.
For the graphical front panel, the remaining connections refer to TCP connections only.
— The number of IEC 61850 connections remaining.
MMS TCP
— The maximum number of PMU TCP connections matches the number of aggregators. The maximum number of
PMU TCP
aggregators for the N60 is 4. The maximum number for the C60 is 2. The maximum number is 1 for other products with a
PMU. The remaining number of aggregators displays here.

6.3.19 Parallel Redundancy Protocol (PRP)

The Parallel Redundancy Protocol (PRP) defines a redundancy protocol for high availability in substation automation
networks.
ACTUAL VALUES  STATUS  PRP STATUS
 PRP STATUS
6-10
INCIPIENT FAULT 1
PH A FAULTS: 0
INCIPIENT FAULT 1
PH B FAULTS: 0
INCIPIENT FAULT 1
PH C FAULTS: 0
COMMANDS  CLEAR RECORDS  CLEAR INCIPENT FAULT COUNTERS
MMS TCP(max 5)
5
MODBUS TCP (max 4)
4
DNP TCP(max 2)
2
IEC-104 TCP(max 2)
2
PMU TCP
1
SFTP (max 4)
4
Total Rx Port A:
0
Range: 0 to 65535 in steps of 1
Range: 0 to 65535 in steps of 1
Range: 0 to 65535 in steps of 1
Range: 0 to 5
Range: 0 to 4
Range: 0 to 2
Range: 0 to 2
Range: 1 to 4
Range: 0 to 4
Range: 0 to 4G, blank if PRP disabled
L30 LINE CURRENT DIFFERENTIAL SYSTEM – INSTRUCTION MANUAL
CHAPTER 6: ACTUAL VALUES
command.