<Toc> <Ind>
4.3
Ceramic, Brick, Glass & Cement Furnaces/Kilns)
a) Rotary type lime kiln
The O
Careful attention to detector mounting position and orientation is required due to the presence of
large amounts of abrasive particulates and intrusion air.
Rotary type lime kiln
Temperature: 250 to 500°C* 1
Note 1: Depending on the kiln, there will be cases when the temperature
All Rights Reserved. Copyright © 2004, Yokogawa Electric Corporation
analyzer is used for combustion monitoring to conserve energy.
2
Sample point
Kiln end
Raw Materials
Exhaust
Gas
at the measuring point will be 600°C or greater (600 to 750°C).
Under these conditions, the high-temperature type should be used.
System type
L2, L3
(H2, H3)
Intrusion Air
Intrusion Air
Exhaust
Gas
4. Applications
Detector
D4
Combustion monitoring
(D3, D5, D6)
F0407.EPS
TI 11M12A01-01E
4-9
Objective
T0407.EPS
May 31,2004-00