B) Cement Kiln (Cyclone Outlet Gas) - YOKOGAWA ZR22G Technical Information

Direct in situ zirconia
Hide thumbs Also See for ZR22G:
Table of Contents

Advertisement

<Toc> <Ind>

b) Cement kiln (cyclone outlet gas)

Cement production consumes approximately 100 liters or more of fuel (heavy oil) per ton of
cement. Thus, combustion management by means of O
ment.
There are cases in which O
system at the kiln outlet.
All Rights Reserved. Copyright © 2004, Yokogawa Electric Corporation
, CO, and CO
2
Sample point
Cyclone outlet
measurements are performed using a sampling
2
System type
L2, L3
Cement kiln
Temperature: 350 to 400°C
Pressure: –3 to 5 kPa
3
Dust:
200 g/Nm
CO:
0.2%
4. Application
analyzers has become a critical ele-
2
Detector
D4, (D3)
Combustion monitoring
TI 11M12A01-01E
4-10
Objective
T0410.EPS
F0410.EPS
May 31, 2004-00

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zr402g

Table of Contents