System Configurations; Zr402G Direct In Situ Zirconia Oxygen Analyzer System Block Diagrams - YOKOGAWA ZR22G Technical Information

Direct in situ zirconia
Hide thumbs Also See for ZR22G:
Table of Contents

Advertisement

<Toc> <Ind>
3.

System Configurations

This section includes two types of system selection guides for direct in situ zirconia
oxygen analyzers. The reader should refer first the examples of system selection by
application, and then examine the system block diagram and component device overviews.
3.1
ZR402G Direct In Situ Zirconia Oxygen Analyzer System
Block Diagrams
(1) System Selection Examples, by Application
Boiler (fuel oil, gas)
Common
Boiler (pulverized coal, fluidized bed)
Boiler (bark, wood scrap)
Heating furnaces & soaking pits
Iron & steel
Hot blast stove
Coke ovens & annealing furnaces
Sintering furnace
Heating, sintering, & melting furnaces
Non-ferrous metals
Coal kilns (rotary & vertical)
Ceramic, brick,
glass, & cement
Cement kilns (cyclone outlet)
manufacture
Glass melting furnaces (inside furnace)
Glass melting furnaces (flue)
Ceramic firing furnaces
Petroleum/
Fired heaters & cracking furnaces
Petrochemical
Black liquor recovery boilers
Pulp & paper
Electrical generating boilers (window box)
Other
Garbage & sludge incinerators
Oxyten enrichment equipment
Note 1: Sampling system is required due to the high pressure.
The symbols such as L1 and D1 used in "the Types of System Configuration and Detector"
are only applicable in this Technical Information document for quick reference. They do not
appear in other literatures including the bulletin, general specifications, or user's manual.
All Rights Reserved. Copyright © 2004, Yokogawa Electric Corporation
3. System Configurations
General-purpose detector
(0 to 700°C)
System types
Detector
L1, L2, L3
D1, (D2)
L2, L3
D4
L2, L3
D3, (D1)
L2, L3
L2, L3
D1
L2, L3
D1, (D2)
L2, L3
D1, (D4)
L2, L3
D1, (D4)
L2, L3
D4, (D3)
L2, L3
D4, (D3)
L2, L3
L2, L3
L2, L3
L2, L3
D1, (D2)
L2, L3
D3, (D4)
L2, L3
D1
L2, L3
D1, D3
L2, L3
The meanings of these codes are explained on the pages that follow.
3-1
High-temperature detector
(0 to 1400°C)
System types
Detector
H2, H3
H2, H3
H2, H3
H2, H3
D5
H2, H3
H2, H3
D6, (D7)
H2, H3
H2, H3
D5, (D6)
H2, H3
(D5, D6)
H2, H3
H2, H3
D5, (D6)
H2, H3
D5, (D6)
H2, H3
D5, (D6)
H2, H3
D5, (D6)
H2, H3
H2, H3
H2, H3
D5
D7 *1
H2, H3
T0301.EPS
TI 11M12A01-01E
May 31,2004-00

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zr402g

Table of Contents