7. Troubleshooting   
Following are a few common problems that may occur during operation. Here are some 
suggestions for easy troubleshooting: 
A. The fixture does not work, no light   
1. Check the connection of power and main fuse. 
2. Measure the mains voltage on the main connector. 
B. Not responding to DMX controller 
1. DMX LED should be on. If not, check DMX connectors, cables to see if link properly. 
2. If  the  DMX  LED  is  on  and  no  response  to  the  channel,  check  the  address  settings  and           
DMX polarity. 
3. If you have intermittent DMX signal problems, check the pins on connectors or on PCB of the 
fixture or the previous one. 
4. Try to use another DMX controller.     
5. Check  if  the  DMX  cables  run  near  or  run  alongside  to  high  voltage  cables  that  may  cause 
damage or interference to DMX interface circuit.   
C. Some fixtures don't respond to the easy controller   
1. You may have a break in the DMX cabling. Check the LED for the response of the master/ slave 
mode signal. 
2. Wrong DMX address in the fixture. Set the proper address. 
D. No response to the sound 
1. Make sure the fixture does not receive DMX signal. 
2. Check microphone to see if it is good by tapping the microphone. 
E. One of the channels is not working well 
1. The stepper motor might be damaged or the cable connected to the PCB is broken. 
2. The motor's drive IC on the PCB might be out of condition. 
 